MIL-M-38510/3808
NOTES:
1. Clock input pulse characteristics: t1 = t0 = 6 ±1.5 ns; tP(CLOCK) = 14 ns; PRR ≤ 1 MHz.
2. Clear input pulse characteristics: t1 = t0 = 6 ±1.5 ns; tP(CLEAR) = 20 ns.
3. For fMAX, the clock input pulse characteristics are as follows: t1 = t0 = 3 ±1.5 ns; for 25°C, tP(CLOCK) = 12.5 ns; PRR = 40 MHz; for -55/+125°C, tP(CLOCK) = 14.5 ns; PRR = 35 MHz.
4. CL = 50 pF ±10%. including scope probe, wiring, and stray capacitance without package in test fixture.
5. RL = 499n ±1%.
6. Voltage measurements are to be made with respect to network ground terminal.
7. Data and load inputs may be used to preset the device to the required count prior to test.
FIGURE 5. Switching time test circuit and waveforms for device types 01 and 02.
25