MIL-M-38510/380B
DEVICE TYPE 04
OPERATION |
Inputs at time tn |
Outputs at time tn + 1 |
||||||||||||||||
G |
ACLR |
ALOAD |
SCLR |
SLOAD |
ENT |
ENP |
CLK |
A |
B |
C |
D |
QA |
QB |
QC |
QD |
RCO |
CCO |
|
Q OUTPUTS DISABLED note 2 |
H |
X |
X |
X |
X |
X |
X |
X |
X |
X |
X |
X |
Z |
Z |
Z |
Z |
H if cnt=15 L if cnt , 15 |
note 1 |
ASYNCHRONOUS CLEAR |
L |
L |
X |
X |
X |
X |
X |
X |
X |
X |
X |
X |
L |
L |
L |
L |
L |
L |
ASYNCHRONOUS LOAD |
L |
H |
L |
X |
X |
X |
X |
X |
X |
X |
X |
X |
A |
B |
C |
D |
H if cnt=15 L if cnt , 15 |
note 1 |
SYNCHRONOUS CLEAR |
L |
H |
H |
L |
X |
X |
X |
t |
X |
X |
X |
X |
L |
L |
L |
L |
L |
L |
SYNCHRONOUS LOAD |
L |
H |
H |
H |
L |
X |
X |
t |
X |
X |
X |
X |
A |
B |
C |
D |
H if cnt=15 L if cnt , 15 |
note 1 |
COUNT |
L |
H |
H |
H |
H |
H |
H |
t |
X |
X |
X |
X |
Previous count plus 1 |
H if cnt=15 L if cnt , 15 |
note 1 |
|||
INHIBIT COUNTING |
L |
H |
H |
H |
H |
X |
L |
X |
X |
X |
X |
X |
No change |
H if cnt=15 L if cnt , 15 |
note 1 |
|||
L |
H |
H |
H |
H |
L |
X |
X |
X |
X |
X |
X |
|||||||
L |
H |
H |
H |
H |
L |
L |
X |
X |
X |
X |
X |
NOTES:
1. CCO produces a high level pulse for a duration equal to that of the low level of the clock when RCO is high and the counter is enabled, otherwise CCO is high.
2. Counting continues.
COUNT UP SEQUENCE |
|||||
QA |
QB |
QC |
QD |
RCO |
CCO |
L |
L |
L |
L |
L |
L |
L |
L |
L |
H |
L |
L |
L |
L |
H |
L |
L |
L |
L |
L |
H |
H |
L |
L |
L |
H |
L |
L |
L |
L |
L |
H |
L |
H |
L |
L |
L |
H |
H |
L |
L |
L |
L |
H |
H |
H |
L |
L |
H |
L |
L |
L |
L |
L |
H |
L |
L |
H |
L |
L |
H |
L |
H |
L |
L |
L |
H |
L |
H |
H |
L |
L |
H |
H |
L |
L |
L |
L |
H |
H |
L |
H |
L |
L |
H |
H |
H |
L |
L |
L |
H |
H |
H |
H |
H |
note 1 |
FIGURE 3. Truth tables - Continued.
19
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business