MIL-M-3851O/316E
Device type O1 and O4
Inputs |
Outputs |
||
D |
Enable |
Q |
Q |
L |
H |
L |
H |
H |
H |
H |
L |
x |
L |
QO |
QO |
H = high level, L = low level, x = irrelevant
QO = the level of Q before the high-to-low transition of enable
Device type O2
Inputs |
Outputs |
|
St |
R |
Q |
H |
H |
QO |
L |
H |
H |
H |
L |
L |
L |
L |
H* |
H = high level, L = low level, QO = the level of Q before the indicated input conditions were established.
* This output level is pseudo stable; that is, it may not persist when the
S and R inputs return to their inactive (high) level. t For latches with double S inputs:
H = both S inputs high
L = one or both S inputs low
FIGURE 2. Truth tables.