TABLE III. Group A inspection for device type 07 - Continued.
Terminal conditions (pins not designated may be high 2.0 V or low σ 0.7 V or open).
Subgroup |
Symbol |
MIL-STD- 883 method |
Cases A,B,C,D |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
Measured terminal |
Limits |
Unit |
|
Case 1/ X and 2 |
2 |
3 |
4 |
6 |
8 |
9 |
10 |
12 |
13 |
14 |
16 |
18 |
19 |
20 |
|||||||
Test no. |
1A |
1B |
NC |
1C |
1D |
1Y |
GND |
2Y |
2A |
2B |
NC |
2C |
2D |
VCC |
Min |
Max |
|||||
9 Tc = 25°C |
tPHL |
3003 Fig. 3 " " " " " " |
47 |
IN |
2.7 V |
2.7 V |
2.7 V |
OUT |
GND |
2.7 V |
2.7 V |
2.7 V |
2.7 V |
5.0 V |
1A to 1Y |
2 |
17 |
ns |
|||
48 |
2.7 V |
IN |
2.7 V |
" |
" |
" |
" |
" |
" |
" |
" |
1B to 1Y |
" |
" |
" |
||||||
49 |
" |
2.7 V |
IN |
" |
" |
" |
" |
" |
" |
" |
" |
1C to 1Y |
" |
" |
" |
||||||
50 |
" |
" |
2.7 V |
IN |
" |
" |
" |
" |
" |
" |
" |
1D to 1Y |
" |
" |
" |
||||||
51 |
" |
" |
" |
2.7 V |
" |
OUT |
IN |
" |
" |
" |
" |
2A to 2Y |
" |
" |
" |
||||||
52 |
" |
" |
" |
" |
" |
" |
2.7 V |
IN |
" |
" |
" |
2B to 2Y |
" |
" |
" |
||||||
53 |
" |
" |
" |
" |
" |
" |
" |
2.7 V |
IN |
" |
" |
2C to 2Y |
" |
" |
" |
||||||
54 |
" |
" |
" |
" |
" |
" |
" |
" |
2.7 V |
IN |
" |
2D to 2Y |
" |
" |
" |
||||||
tPLH |
" " " " " " " " |
55 |
IN |
" |
" |
" |
OUT |
" |
" |
" |
" |
2.7 V |
" |
1A to 1Y |
" |
15 |
" |
||||
56 |
2.7 V |
IN |
" |
" |
" |
" |
" |
" |
" |
" |
" |
1B to 1Y |
" |
" |
" |
||||||
57 |
" |
2.7 V |
IN |
" |
" |
" |
" |
" |
" |
" |
" |
1C to 1Y |
" |
" |
" |
||||||
58 |
" |
" |
2.7 V |
IN |
" |
" |
" |
" |
" |
" |
" |
1D to 1Y |
" |
" |
" |
||||||
59 |
" |
" |
" |
2.7 V |
" |
OUT |
IN |
" |
" |
" |
" |
2A to 2Y |
" |
" |
" |
||||||
60 |
" |
" |
" |
" |
" |
" |
2.7 V |
IN |
" |
" |
" |
2B to 2Y |
" |
" |
" |
||||||
61 |
" |
" |
" |
" |
" |
" |
" |
2.7 V |
IN |
" |
" |
2C to 2Y |
" |
" |
" |
||||||
62 |
" |
" |
" |
" |
" |
" |
" |
" |
2.7 V |
IN |
" |
2D to 2Y |
" |
" |
" |
||||||
10 Tc = 125°C |
tPHL |
3003 Fig. 3 " " " " " " |
63 |
IN |
" |
" |
" |
OUT |
" |
" |
" |
" |
2.7 V |
5.0 V |
1A to 1Y |
" |
24 |
" |
|||
64 |
2.7 V |
IN |
" |
" |
" |
" |
" |
" |
" |
" |
" |
1B to 1Y |
" |
" |
" |
||||||
65 |
" |
2.7 V |
IN |
" |
" |
" |
" |
" |
" |
" |
" |
1C to 1Y |
" |
" |
" |
||||||
66 |
" |
" |
2.7 V |
IN |
" |
" |
" |
" |
" |
" |
" |
1D to 1Y |
" |
" |
" |
||||||
67 |
" |
" |
" |
2.7 V |
" |
OUT |
IN |
" |
" |
" |
" |
2A to 2Y |
" |
" |
" |
||||||
68 |
" |
" |
" |
" |
" |
" |
2.7 V |
IN |
" |
" |
" |
2B to 2Y |
" |
" |
" |
||||||
69 |
" |
" |
" |
" |
" |
" |
" |
2.7 V |
IN |
" |
" |
2C to 2Y |
" |
" |
" |
||||||
70 |
" |
" |
" |
" |
" |
" |
" |
" |
2.7 V |
IN |
" |
2D to 2Y |
" |
" |
" |
||||||
tPLH |
" " " " " " " " |
71 |
IN |
" |
" |
" |
OUT |
" |
" |
" |
" |
2.7 V |
" |
1A to 1Y |
" |
20 |
" |
||||
72 |
2.7 V |
IN |
" |
" |
" |
" |
" |
" |
" |
" |
" |
1B to 1Y |
" |
" |
" |
||||||
73 |
" |
2.7 V |
IN |
" |
" |
" |
" |
" |
" |
" |
" |
1C to 1Y |
" |
" |
" |
||||||
74 |
" |
" |
2.7 V |
IN |
" |
" |
" |
" |
" |
" |
" |
1D to 1Y |
" |
" |
" |
||||||
75 |
" |
" |
" |
2.7 V |
" |
OUT |
IN |
" |
" |
" |
" |
2A to 2Y |
" |
" |
" |
||||||
76 |
" |
" |
" |
" |
" |
" |
2.7 V |
IN |
" |
" |
" |
2B to 2Y |
" |
" |
" |
||||||
77 |
" |
" |
" |
" |
" |
" |
" |
2.7 V |
IN |
" |
" |
2C to 2Y |
" |
" |
" |
||||||
78 |
" |
" |
" |
" |
" |
" |
" |
" |
2.7 V |
IN |
" |
2D to 2Y |
" |
" |
" |
||||||
11 |
Same tests, terminal conditions and limits as for subgroup 10, except TC = -55° C. |
1/ For case X and 2, pins not referenced are NC.
2/ IIL limits in μA are as follows:
Measured terminal |
Min/max limits for circuit |
|||||
A |
B |
C |
D |
E |
F |
|
1A, 1B, 1C, 1D, 2A, 2B, 2C, 2D |
-120/-360 |
-30/-300 |
-160/-400 |
-120/-360 |
-150/-380 |
-100/-340 |
3/ IOS limits for circuit C: -20/-100 mA; for circuits A, B, D, E, and F: -15/-100 mA.