TABLE III. Group A inspection for device type 02.
Terminal conditions (pins not designated may be high � 2.0V or low s 0.8 V or open).
Subgroup |
Symbol |
MIL- ST0-883 method |
Case E & F |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
Meas. terminal |
Test limits |
||
Test No. |
Clear |
1Q |
1 Q |
10 |
20 |
2 Q |
2Q |
GN0 |
Clock |
3Q |
3 Q |
30 |
40 |
4 Q |
4Q |
VCC |
Min |
Max |
Unit |
||||
10 TC = 125°C |
fMAX 5/ " " |
Fig 4 " " " |
91 92 93 94 |
5.0 V " " " |
OUT |
IN |
IN |
OUT |
GN0 " " " |
IN " " " |
OUT |
IN |
IN |
OUT |
5.0 V " " " |
1Q 2Q 3Q 4Q |
25 " " " |
MHz " " " |
|||||
tPLH1 " " " |
3003 Fig 7 " " |
95 96 97 98 |
IN " " " |
OUT |
5.0 V |
5.0 V |
OUT |
" " " " |
" " " " |
OUT |
5.0 V |
5.0 V |
OUT |
" " " " |
Clear-1 Q Clear-2 Q Clear-3 Q Clear-4 Q |
5 " " " |
36 " " " |
ns " " " |
|||||
tPHL1 " " " |
" " " " |
99 100 101 102 |
" " " " |
OUT |
5.0 V |
5.0 V |
OUT |
" " " " |
" " " " |
OUT |
5.0 V |
5.0 V |
OUT |
" " " " |
Clear-1Q Clear-2Q Clear-3Q Clear-4Q |
" " " " |
50 " " " |
" " " " |
|||||
tPLH2, tPHL2 " " |
3003 Fig 4 & 5 " " |
103 & 104 105 & 106 107 & 108 109 & 110 |
5.0 V " " " |
OUT |
IN |
IN |
OUT |
" " " " |
" " " " |
OUT |
IN |
IN |
OUT |
" " " " |
Clock-1Q Clock-2Q Clock-3Q Clock-4Q |
" " " " |
43 " " " |
" " " " |
|||||
tPLH3, tPHL3 " " |
" " " " |
111 & 112 113 & 114 115 & 116 117 & 118 |
" " " " |
OUT |
IN |
IN |
OUT |
" " " " |
" " " " |
OUT |
IN |
IN |
OUT |
" " " " |
Clock-1 Q Clock-2 Q Clock-3 Q Clock-4 Q |
" " " " |
" " " " |
" " " " |
|||||
11 |
Same tests, terminal conditions and limits as subgroup 10, except TC = -55°C. |
1/ B = Momentary GN0, then VCC.
2/ The tests in subgroups 7 and 8 shall be performed in the sequence specified.
3/ Output voltages shall be either:
(a) H = 2.4 V minimum and L = 0.4 V maximum when using a high speed checker double comparator, or
(b) H > 1.5 V and L < 1.5 V when using a high speed checker single comparator.
4/ Only a summary of attributes data is required.
5/ fMAX minimum limit specified is the frequency of the input pulse. The output frequency shall be one half of the input frequency.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business