TABLE III. Group A inspection for device type 02. 1/
Subgroup |
Symbol |
MIL- STD-883 method |
Cases E, F |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
Meas. terminal |
Test limits |
||
Test No. |
G 1 |
P 1 |
G 0 |
P 0 |
G 3 |
P 3 |
P |
GND |
Cn+z |
G |
Cn+y |
Cn+x |
Cn |
G 2 |
P 2 |
VCC |
Min |
Max |
Unit |
||||
10 TC = 125°C |
tPLH2 tPHL2 tPLH2 tPHL2 tPLH2 tPHL2 tPLH2 tPHL2 tPLH3 tPHL3 tPLH3 tPHL3 tPLH3 tPHL3 tPLH3 tPHL3 tPLH3 tPHL3 tPLH3 tPHL3 |
3003 Fig 4 " " " " " " " " " " " " " " " " " " |
130 131 132 133 134 135 136 137 138 139 140 141 142 143 144 145 146 147 148 149 |
4.5 V " " " " " " " " " " " " " IN " " " 4.5 V " |
GND " IN " " " GND " " " " " " " " " " " " " |
4.5 V " " " " " " " IN " " " " " 4.5 V " " " " " |
IN IN GND " " " " " " " " " " " " " " " " " |
4.5 V " " " " " " " " " " " " " " " " " " " |
4.5 V " " " " " " " " " " " " " " " " " " " |
GND " " " " " " " " " " " " " " " " " " " |
OUT OUT OUT " " " OUT OUT OUT " " " |
OUT OUT OUT OUT OUT OUT |
OUT OUT |
4.5 V " " " " " " " GND " " " " " " " " " " " |
4.5 V " " " " " " " " " " " " " " " " " IN IN |
GND " " " " " IN IN GND " " " " " " " " " " " |
5.0 V " " " " " " " " " " " " " " " " " " " |
P 0 to Cn+z P 0 to Cn+z P 1 to Cn+y P 1 to Cn+y P 1 to Cn+z P 1 to Cn+z P 2 to Cn+z P 2 to Cn+z G 0 to Cn+x G 0 to Cn+x G 0 to Cn+y G 0 to Cn+y G 0 to Cn+z G 0 to Cn+z G 1 to Cn+y G 1 to Cn+y G 1 to Cn+z G 1 to Cn+z G 2 to Cn+z G 2 to Cn+z |
3 " " " " " " " " " " " " " " " " " " " |
25 32 25 32 25 32 25 32 25 32 25 32 25 32 25 32 25 32 25 32 |
ns " " " " " " " " " " " " " " " " " " " |
See notes at end of table for device type 02.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business