TABLE III. Group A inspection for device type 01 - Continued. 1/
Subgroup |
Symbol |
MIL- STD- 883 method |
Case J, K, L, Z |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
Meas terminal |
Test limits |
||
Test No. |
B 0 |
A 0 |
S3 |
S2 |
S1 |
S0 |
Cn |
M |
F 0 |
F 1 |
F 2 |
GND |
Min |
Max |
Unit |
||||
10 TC = 125°C |
tPHL6 |
3003 (Fig 4) " " " " " " |
362 363 364 365 366 367 368 369 |
4.5 V GND " " IN GND " " |
IN GND " " " " " " |
GND " " " " " " " |
4.5 V " " " " " " " |
4.5 V " " " " " " " |
GND " " " " " " " |
GND " " " " " " " |
GND " " " " " " " |
GND " " " " " " " |
A0 to G A1 to G A2 to G A3 to G B0 to G B1 to G B2 to G B3 to G |
7 " " " " " " " |
40 " " " " " " " |
ns " " " " " " " |
|||
tPLH6 |
" " " " " " " " |
370 371 372 373 374 375 376 377 |
4.5 V GND " " IN GND " " |
IN GND " " " " " " |
GND " " " " " " " |
4.5 V " " " " " " " |
4.5 V " " " " " " " |
GND " " " " " " " |
GND " " " " " " " |
GND " " " " " " " |
" " " " " " " " |
A0 to G A1 to G A2 to G A3 to G B0 to G B1 to G B2 to G B3 to G |
7 " " " " " " " |
40 " " " " " " " |
ns " " " " " " " |
||||
tPHL7 tPLH7 |
" " |
378 379 |
GND GND |
4.5 V 4.5 V |
4.5 V 4.5 V |
GND GND |
GND GND |
4.5 V 4.5 V |
IN IN |
GND GND |
OUT OUT |
" " |
Cnto F0 Cnto F0 |
7 7 |
25 27 |
ns ns |
|||
tPHL8 |
" " " " " " " " |
380 381 382 383 384 385 386 387 |
GND " " " IN GND " " |
IN 4.5 V " " " " " " |
GND " " " " " " " |
4.5 V " " " " " " " |
4.5 V " " " " " " " |
GND " " " " " " " |
GND " " " " " " " |
GND " " " " " " " |
" " " " " " " " |
A0 to A = B A1 to A = B A2 to A = B A3 to A = B B0 to A = B B1 to A = B B2 to A = B B3 to A = B |
7 " " " " " " " |
76 " " " " " " " |
ns " " " " " " " |
See notes at end of table for device type 01.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business