TABLE III. Group A inspection for device type 01 - Continued. 1/
Subgroup |
Symbol |
MIL- STD- 883 method |
Case J, K, L, Z |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
Meas terminal |
Test limits |
||
Test No. |
B 0 |
A 0 |
S3 |
S2 |
S1 |
S0 |
Cn |
M |
F 0 |
F 1 |
F 2 |
GND |
Min |
Max |
Unit |
||||
10 TC = 125°C |
tPHL1 |
3003 (Fig 4) " " " " " " |
282 283 284 285 286 287 288 289 |
4.5 V " " " IN 4.5 V " " |
IN 4.5 V " " " " " " |
4.5 V " " " " " " " |
GND " " " " " " " |
GND " " " " " " " |
4.5 V " " " " " " " |
GND " " " " " " " |
GND " " " " " " " |
OUT OUT |
OUT OUT |
OUT OUT |
GND " " " " " " " |
A0 to F0 A1 to F1 A2to F2 A3 to F3 B0to F0 B1to F1 B2to F2 B3to F3 |
7 " " " " " " " |
46 " " " " " " " |
ns " " " " " " " |
tPLH1 |
" " " " " " " " |
290 291 292 293 294 295 296 297 |
4.5 V " " " IN 4.5 V " " |
IN 4.5 V " " " " " " |
4.5 V " " " " " " " |
GND " " " " " " " |
GND " " " " " " " |
4.5 V " " " " " " " |
GND " " " " " " " |
GND " " " " " " " |
OUT OUT |
OUT OUT |
OUT OUT |
" " " " " " " " |
A0 to F0 A1 to F1 A2to F2 A3 to F3 B0to F0 B1to F1 B2to F2 B3to F3 |
7 " " " " " " " |
60 " " " " " " " |
ns " " " " " " " |
See notes at end of table for device type 01.