TABLE III. Group A inspection for device type 01 - Continued. 1/
Subgroup |
Symbol |
MIL- STD- 883 method |
Case J, K, L, Z |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
Meas terminal |
Test limits |
||
Test No. |
B 0 |
A 0 |
S3 |
S2 |
S1 |
S0 |
Cn |
M |
F 0 |
F 1 |
F 2 |
GND |
Min |
Max |
Unit |
||||
9 TC = 25°C |
tPHL4 |
3003 (Fig 4) " " " " " " |
164 165 166 167 168 169 170 171 |
GND " " " IN GND " " |
IN GND " " 4.5 V GND " " |
GND " " " " " " " |
4.5 V " " " " " " " |
4.5 V " " " " " " " |
GND " " " " " " " |
GND " " " " " " " |
GND " " " " " " " |
GND " " " " " " " |
A0 to P A1 to P A2 to P A3 to P B0 to P B1 to P B2 to P B3 to P |
7 " " " " " " " |
30 " " " " " " " |
ns " " " " " " " |
|||
tPLH4 |
" " " " " " " " |
172 173 174 175 176 177 178 179 |
GND " " " IN GND " " |
IN GND " " 4.5 V GND " " |
GND " " " " " " " |
4.5 V " " " " " " " |
4.5 V " " " " " " " |
GND " " " " " " " |
GND " " " " " " " |
GND " " " " " " " |
" " " " " " " " |
A0 to P A1 to P A2 to P A3 to P B0 to P B1 to P B2 to P B3 to P |
7 " " " " " " " |
30 " " " " " " " |
ns " " " " " " " |
||||
tPHL5 |
" " " " " " " " |
180 181 182 183 184 185 186 187 |
GND 4.5 V " " IN 4.5 V " " |
IN GND " " " " " " |
4.5 V " " " " " " " |
GND " " " " " " " |
GND " " " " " " " |
4.5 V " " " " " " " |
GND " " " " " " " |
GND " " " " " " " |
" " " " " " " " |
A0 to G A1 to G A2 to G A3 to G B0 to G B1 to G B2 to G B3 to G |
7 " " " " " " " |
25 " " " " " " " |
ns " " " " " " " |
||||
tPLH5 |
" " " " " " " " |
188 189 190 191 192 193 194 195 |
GND 4.5 V " " IN 4.5 V " " |
IN GND " " " " " " |
4.5 V " " " " " " " |
GND " " " " " " " |
GND " " " " " " " |
4.5 V " " " " " " " |
GND " " " " " " " |
GND " " " " " " " |
" " " " " " " " |
A0 to G A1 to G A2 to G A3 to G B0 to G B1 to G B2 to G B3 to G |
7 " " " " " " " |
25 " " " " " " " |
ns " " " " " " " |
See notes at end of table for device type 01.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business