TABLE III. Group A inspection for all device types - Continued.
Subgroup |
Symbol |
MIL-STD- 883 method |
Test no. |
Adapter pin numbers 14I |
Relays closed 14I |
Pin measured |
Devices 01, 03 limits |
Device 02 limits 1I |
||||||||||||||||
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
|||||||||||||||||
Devices |
Devices |
Devices |
||||||||||||||||||||||
01,03 |
02 |
01,03 |
02 |
01,03 |
02 |
No. |
Value |
Unit |
Min |
Max |
Unit |
Min |
Max |
Unit |
||||||||||
11 TA = -55°C |
tdis |
125 126 127 128 |
GND " " " |
4.5 16.5 4.5 16.5 |
5 15 5 15 |
See fig. 6 " " |
See fig. 6 " " |
1,2,3,5, 8,10 " 1,2,3,6, 9,10 " |
4 " " " |
tdis " " " |
µs µs ms ms |
57.5 57.5 5.40 5.40 |
80.0 80.0 7.70 7.70 |
µs µs ms ms |
57.5 57.5 5.40 5.40 |
80.0 80.0 7.70 7.70 |
µs µs ms ms |
|||||||
dtch I dT |
129 |
" |
16.5 |
15 |
See fig. 6 10I |
1,2,3,5, 8,10 |
4 |
dtch I dT |
ns I °C |
-68 |
68 |
ns I °C |
-68 |
68 |
ns I °C |
|||||||||
dtD(OH)MI dT |
130 |
GND |
--- |
15 |
For device 02 only 13I see fig. 4 |
1,3,5,7, 10,11 |
4 |
dtD(OH)MI dT |
ns I °C |
--- --- |
--- --- |
--- --- |
-20 |
+20 |
ns I °C |
|||||||||
tres |
131 |
" |
16.5 |
15 |
See fig. 7 |
See fig. 7 |
1,3,5,7, 11 |
4 |
tres |
µs |
--- |
1.5 |
µs |
--- |
1.5 |
µs |
1I Limits apply to both halves of device type 02 independently.
2I The voltage at adapter pin 8 is swept downward from a voltage > 2I3 VCC. VTR is measured when the output switches to the "high" state.
3I The voltage at adapter pin 8 is swept upward from a voltage < 1I3 VCC. VTH is measured when the output switches to the "low" state.
4I The application of GND to test circuit pin 5 causes the output to be reset (latched low). Measure IR into adapter pin 5.
5I dtD(OH) I dVCC = ( tD(OH) at VCC = 16.5 V - tD(OH) at VCC = 4.5 V ) I ( 16.5 V - 4.5 V ).
6I For 02, dtD(OH) I dVCC = ( tD(OH) at VCC = 15 V - tD(OH) at VCC = 5 V ) I ( 15 V - 5 V ).
7I dtch I dVCC = ( tch at VCC = 16.5 V - tch at 4.5 V ) I ( 16.5 V - 4.5 V ).
8I For 02, dtch I dVCC = ( tch at VCC = 15 V - tch at 5 V ) I ( 15 V - 5 V ).
9I dtD(OH) I dT = ( tD(OH) at 125°C - tD(OH) at 25°C ) I ( 125°C - 25°C ) and ( tD(OH) at 25°C - tD(OH) at -55°C ) I ( 25°C - (-55°C) ).
10I dtch I dT = ( tch at 125°C - tch at 25°C ) I ( 125°C - 25°C ) and ( tch at 25°C - tch at -55°C ) I ( 25°C - (-55°C) ).
11I dtD(OH)M = tD(OH) side "A" - tD(OH) side "B".
12I dtD(OH)M I dVCC = ( dtD(OH) I dVCC ) side "A" - ( dtD(OH) I dVCC ) side "B".
13I dtD(OH)M I dT = ( dtD(OH) I dT ) side "A" - ( dtD(OH) I dT ) side "B".
14I Test circuit pin numbers and relays refer to those shown on figure 3.
15I VOL shall be measured after the output has been low for 100 µs (minimum).
16I ISOURCE for device type 03 = -60 mA.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business