MIL-M-38510/109B
NOTES:
1. The timing capacitor voltage measurement (threshold) shall be made on pin 7 of the test adapter.
2. The timing measurement (output) shall be made at pin 4 of the test adapter.
FIGURE 6. Waveforms for timing parameters (astable).
NOTES:
1. Reset pulse rise and fall times shall be ≤ 10 ns.
2. Reset threshold are checked by applying the specified reset levels and verifying
a. Output high after trigger pulse and before reset goes low and
b. Output goes low stays low 2 µseconds minimum after rest is returned high.
3. This limit only applies during test for tRES.
4. This pulse shall be applied to pin 7 of the test adapter.
5. This measurement shall be made on pin 4 of the test adapter.
6. This pulse shall be applied to pin 5 of the test adapter.
7. A/B means value "A" for VCC = 15 V or 16.5 V and "B" for VCC = 4.5 V or 5 V.
FIGURE 7. Waveforms for reset tests.
18
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business