MIL-M-38510/751B
NOTES:
1. CL = 50pF or equivalent (includes test jig and probe capacitance).
2. RL = 500n or equivalent.
3. RT = 50n or equivalent.
4. Input signal from pulse generator: VIN = 0.0 V to VCC; PRR ≤ 10 MHz; duty cycle = 50 percent; tr ≤ 3.0 ns, tf ≤ 3.0 ns.
5. Timing parameters shall be tested at a minimum input frequency of 1 MHz.
FIGURE 4. Switching waveforms and test circuit.
13