TA8LE III. Group A inspection for device type 01 - Continued.
Symbol |
MIL- STD- 883 method |
Case 2 |
Terminal conditions 11 |
Measured terminal |
Test limits |
Unit |
||||||||||||||||||
2 |
3 |
4 |
6 |
8 |
9 |
10 |
12 |
13 |
14 |
16 |
18 |
19 |
20 |
Subgroup 1 TC = +25°C |
Subgroup 2 TC = +125°C |
Subgroup 3 TC = -55°C |
||||||||
Cases C,D |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
||||||||||
Test no. |
1A |
18 |
1Y |
2A |
28 |
2Y |
GND |
3Y |
3A |
38 |
4Y |
4A |
48 |
VCC |
Min |
Max |
Min |
Max |
Min |
Max |
||||
IIL |
3009 |
56 57 58 59 60 61 62 63 |
GND 6V |
6V GND |
GND 6V |
6V GND |
GND " " " " " " " |
GND 6V |
6V GND |
GND 6V |
6V GND |
6V " " " " " " " |
1A 18 2A 28 3A 38 4A 48 |
-.05 " " " " " " " |
-0.1 " " " " " " " |
µA " " " " " " " |
||||||||
Subgroup 4 TC = +25°C |
||||||||||||||||||||||||
Min |
Max |
|||||||||||||||||||||||
Ci |
3012 |
64 65 66 67 68 69 70 71 |
21 |
21 |
21 |
21 |
GND " " " " " " " |
21 |
21 |
21 |
21 |
GND " " " " " " " |
1A 18 2A 28 3A 38 4A 48 |
10 " " " " " " " |
pF " " " " " " " |
|||||||||
Subgroup 9 TC = +25°C 31 |
Subgroup 10 TC = +125°C |
Subgroup 11 TC = -55°C 31 |
||||||||||||||||||||||
Min |
Max |
Min |
Max |
Min |
Max |
|||||||||||||||||||
tPHL |
3003 (Fig. 3) |
72 73 74 75 76 77 78 79 |
IN GND |
GND IN |
OUT OUT |
IN GND |
GND IN |
OUT OUT |
GND " " " " " " " |
OUT OUT |
IN GND |
GND IN |
OUT OUT |
IN GND |
GND IN |
4.5V " " " " " " " |
1A to 1Y 18 to 1Y 2A to 2Y 28 to 2Y 3A to 3Y 38 to 3Y 4A to 4Y 48 to 4Y |
3 " " " " " " " |
18 " " " " " " " |
3 " " " " " " " |
23 " " " " " " " |
3 " " " " " " " |
18 " " " " " " " |
ns " " " " " " " |
tPLH |
3003 (Fig. 3) |
80 to 87 |
Same terminal conditions and limits as specified above for tPHL. |
|||||||||||||||||||||
tTLH |
3004 (Fig. 3) |
88 89 90 91 92 93 94 95 |
IN GND |
GND IN |
OUT OUT |
IN GND |
GND IN |
OUT OUT |
GND " " " " " " " |
OUT OUT |
IN GND |
GND IN |
OUT OUT |
IN GND |
GND IN |
4.5V " " " " " " " |
1Y 1Y 2Y 2Y 3Y 3Y 4Y 4Y |
3 " " " " " " " |
15 " " " " " " " |
3 " " " " " " " |
20 " " " " " " " |
3 " " " " " " " |
15 " " " " " " " |
ns " " " " " " " |
tTHL |
3004 (Fig. 3) |
96 to 103 |
Same terminal conditions and limits as specified above for tTLH. |
See footnotes at end of device type 04.