TA8LE III. Group A inspection for device type 05 - Continued.
Symbol |
MIL- STD- 883 method |
Case |
Terminal conditions 1/ |
Measured terminal |
Test limits |
Unit |
||||||||||||||||||
2 |
2 |
3 |
4 |
6 |
8 |
9 |
10 |
12 |
13 |
14 |
16 |
18 |
19 |
20 |
3/ Subgroup 9 TC = +25°C |
Subgroup 10 TC = +125°C |
3/ Subgroup 11 TC = -55°C |
|||||||
C,D |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
||||||||||
Test no. |
1A |
18 |
1Y |
2Y |
2A |
28 |
GND |
3A |
38 |
3Y |
4Y |
4A |
48 |
VCC |
Min |
Max |
Min |
Max |
Min |
Max |
||||
tTHL |
3004 (Fig. 3) |
103 104 105 106 107 108 109 110 |
IN GND |
GND IN |
OUT OUT |
OUT OUT |
IN GND |
GND IN |
GND " " " " " " " |
IN GND |
GND IN |
OUT OUT |
OUT OUT |
IN GND |
GND IN |
4.5V " " " " " " " |
1Y 1Y 2Y 2Y 3Y 3Y 4Y 4Y |
3 " " " " " " " |
15 " " " " " " " |
3 " " " " " " " |
20 " " " " " " " |
3 " " " " " " " |
15 " " " " " " " |
ns " " " " " " " |
tTLH |
3004 (Fig. 3) |
111 to 118 |
Same terminal conditions and limits as specified above for tTHL. |
1/ Input pins not designated shall be high level logic, low level logic, or may be left open provided they do not influence the outcome of the measurement.
Output pins not designated shall be tied to the loads or left open provided they do not influence the outcome of the measurement. Exceptions are as follows:
a. VIC(pos) tests: The GND terminal shall be open. A minimum limit of 0.4 V applies to test being performed on equipment not capable of opening GND pin during test.
b. VIC(neg) tests: The VCC terminal shall be open. c. ICC tests: The output terminal shall be open.
2/ See 4.4.1c. For all type input terminals (e.g., clock, clear, data, etc.), a minimum of 3 inputs of each per device shall be tested.
3/ See 4.4.1d.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business