TA8LE III. Group A inspection for device type 54 - Continued.
Symbol |
MIL- STD- 883 method |
Cases A,C,D T,X,Y |
TERMINAL CONDITIONS 1/ |
Test limits |
Units |
||||||||||||||||||||||||||
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
Measured terminal |
Subgroup 9 TA = 25°C |
Subgroup 10 TA = 125°C |
Subgroup 11 TA = -55°C |
||||||||||||||
Test No. |
1A |
18 |
2A |
28 |
2C |
2Y |
VSS |
1C |
1Y |
3Y |
3A |
38 |
3C |
VDD |
Min |
Max |
Min |
Min |
Max |
Min |
|||||||||||
tPHL " " " " " " " " |
3003 Fig. 3 " " " " " " " |
124 125 126 127 128 129 130 131 132 |
5/ GND " " " " " " " |
GND 5/ GND " " " " " " |
GND " " 5/ GND " " " " |
GND " " " 5/ GND " " " |
GND " " " " 5/ GND " " |
6/ 6/ 6/ |
GND " " " " " " " " |
GND GND 5/ GND " " " " " |
6/ 6/ 6/ |
6/ 6/ 6/ |
GND " " " " " 5/ GND GND |
GND " " " " " " 5/ GND |
GND " " " " " " " 5/ |
5.0V " " " " " " " " |
1A to 1Y 18 to 1Y 1C to 1Y 2A to 2Y 28 to 2Y 2C to 2Y 3A to 3Y 38 to 3Y 3C to 3Y |
10 " " " " " " " " |
210 " " " " " " " " |
14 " " " " " " " " |
315 " " " " " " " " |
10 " " " " " " " " |
210 " " " " " " " " |
ns " " " " " " " " |
|||||||
tPLH " " " " " " " " |
3003 Fig. 3 " " " " " " " |
133 134 135 136 137 138 139 140 141 |
5/ GND " " " " " " " |
GND 5/ GND " " " " " " |
GND " " 5/ GND " " " " |
GND " " " 5/ GND " " " |
GND " " " " 5/ GND " " |
6/ 6/ 6/ |
GND " " " " " " " " |
GND GND 5/ GND " " " " " |
6/ 6/ 6/ |
6/ 6/ 6/ |
GND " " " " " 5/ GND GND |
GND " " " " " " 5/ GND |
GND " " " " " " " 5/ |
5.0V " " " " " " " " |
1A to 1Y 18 to 1Y 1C to 1Y 2A to 2Y 28 to 2Y 2C to 2Y 3A to 3Y 38 to 3Y 3C to 3Y |
10 " " " " " " " " |
210 " " " " " " " " |
14 " " " " " " " " |
315 " " " " " " " " |
10 " " " " " " " " |
210 " " " " " " " " |
" " " " " " " " " |
|||||||
Subgroup 9 TA = 25°C |
Subgroup 10 TA = 125°C |
Subgroup 11 TA = -55°C |
|||||||||||||||||||||||||||||
Min |
Max |
Min |
Max |
Min |
Max |
||||||||||||||||||||||||||
tTHL " " " " " " " " |
3004 Fig. 3 " " " " " " " |
142 143 144 145 146 147 148 149 150 |
5/ GND " " " " " " " |
GND 5/ GND " " " " " " |
GND " " 5/ GND " " " " |
GND " " " 5/ GND " " " |
GND " " " " 5/ GND " " |
6/ 6/ 6/ |
GND " " " " " " " " |
GND GND 5/ GND " " " " " |
6/ 6/ 6/ |
6/ 6/ 6/ |
GND " " " " " 5/ GND GND |
GND " " " " " " 5/ GND |
GND " " " " " " " 5/ |
5.0V " " " " " " " " |
1Y 1Y 1Y 2Y 2Y 2Y 3Y 3Y 3Y |
10 " " " " " " " " |
300 " " " " " " " " |
14 " " " " " " " " |
450 " " " " " " " " |
10 " " " " " " " " |
300 " " " " " " " " |
ns " " " " " " " " |
|||||||
tTLH " " " " " " " " |
" " " " " " " " " |
151 152 153 154 155 156 157 158 159 |
5/ GND " " " " " " " |
GND 5/ GND " " " " " " |
GND " " 5/ GND " " " " |
GND " " " 5/ GND " " " |
GND " " " " 5/ GND GND GND |
6/ 6/ 6/ |
GND " " " " " " " " |
" " 5/ GND " " " " " |
6/ 6/ 6/ |
6/ 6/ 6/ |
GND " " " " " 5/ GND GND |
GND " " " " " " 5/ GND |
GND " " " " " " " 5/ |
5.0V " " " " " " " " |
1Y 1Y 1Y 2Y 2Y 2Y 3Y 3Y 3Y |
10 " " " " " " " " |
410 " " " " " " " " |
14 " " " " " " " " |
615 " " " " " " " " |
10 " " " " " " " " |
410 " " " " " " " " |
" " " " " " " " " |
1/ Input pins not designated may be tied to VCC or GND or may be left open provided they do not influence the outcome of the measurement.
Output pins not designated may be tied to the loads or may be left open provided they do not influence the outcome of the measurement,
except as follows: VIC(pos) tests; the VSS terminals shall be open. VIC(neg) tests; the VDD terminal shall be open. ISS tests; the output terminals shall be open.
2/ When performing quiescent supply current measurements (ISS), the meter shall be placed so that all currents flow thru the meter.
3/ The device manufacturer may, at his option, measure IIL and IIH at 25°C for each individual input or measure all inputs together.
4/ Capacitance bridge between measured terminal and VSS; frequency = 1 MHz.
5/ Pulse conditions - See figure 3.
6/ Loading conditions - See figure 3.