TA8LE III. Group A inspection for device type 52 - Continued.
Symbol MIL-
Cases
TERMINAL CONDITIONS 11 Test limits Units
STD- A,C,D |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
Measured |
Subgroup 1 |
Subgroup 2 |
Subgroup 3 |
||||||
883 |
T,X,Y |
terminal |
TA = 25°C |
TA = 125°C |
TA = -55°C |
|||||||||||||||||||
method |
Test No. |
1A |
18 |
1Y |
2Y |
2A |
28 |
VSS |
3A |
38 |
3Y |
4Y |
4A |
48 |
VDD |
Min |
Max |
Min |
Max |
Min |
Max |
|||
IIL 31 |
3009 |
92 |
GND |
GND |
GND |
GND |
GND |
GND |
GND |
GND |
GND |
18.0V |
All inputs |
-800 |
nA |
|||||||||
together |
||||||||||||||||||||||||
" |
" |
93 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
1A |
-100 |
-100 |
" |
||||||||
" |
" |
94 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
18 |
" |
" |
" |
||||||||
" |
" |
95 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
2A |
" |
" |
" |
||||||||
" |
" |
96 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
28 |
" |
" |
" |
||||||||
" |
" |
97 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
3A |
" |
" |
" |
||||||||
" |
" |
98 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
38 |
" |
" |
" |
||||||||
" |
" |
99 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
4A |
" |
" |
" |
||||||||
" |
" |
100 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
48 |
" |
" |
" |
||||||||
IIH 31 |
3010 |
101 |
18.0V |
18.0V |
18.0V |
18.0V |
" |
18.0V |
18.0V |
18.0V |
18.0V |
" |
All inputs |
800 |
" |
|||||||||
together |
||||||||||||||||||||||||
" |
" |
102 |
18.0V |
GND |
GND |
GND |
" |
GND |
GND |
GND |
GND |
" |
1A |
100 |
100 |
" |
||||||||
" |
" |
103 |
GND |
18.0V |
GND |
GND |
" |
" |
" |
" |
" |
" |
18 |
" |
" |
" |
||||||||
" |
" |
104 |
" |
GND |
18.0V |
GND |
" |
" |
" |
" |
" |
" |
2A |
" |
" |
" |
||||||||
" |
" |
105 |
" |
" |
GND |
18.0V |
" |
" |
" |
" |
" |
" |
28 |
" |
" |
" |
||||||||
" |
" |
106 |
" |
" |
" |
GND |
" |
18.0V |
" |
" |
" |
" |
3A |
" |
" |
" |
||||||||
" |
" |
107 |
" |
" |
" |
" |
" |
GND |
18.0V |
" |
" |
" |
38 |
" |
" |
" |
||||||||
" |
" |
108 |
" |
" |
" |
" |
" |
GND |
GND |
18.0V |
" |
" |
4A |
" |
" |
" |
||||||||
" |
" |
109 |
" |
" |
" |
" |
" |
GND |
GND |
GND |
18.0V |
" |
48 |
" |
" |
" |
CI 3012 " "
" " " " " " " " " "
" "
110 41
111 41
112
113
114
115
116
117
GND "
41 "
41 "
" 41
" 41 "
"
GND "
" " " "
41 "
41 "
Subgroup 4
TA = 25°C
1A 12
18 "
2A "
28 "
3A "
38 "
4A "
48 " Subgroup 9
pF "
" " " " " "
Subgroup 10 Subgroup 11
TA = 25°C
TA = 125°C
TA = -55°C
tPHL |
3003 |
118 |
51 |
GND |
61 |
GND |
GND |
GND |
GND |
GND |
GND |
GND |
5.0V |
1A to 1Y |
13 |
210 |
18 |
315 |
13 |
210 |
ns |
|||
" |
Fig. 3 |
119 |
GND |
51 |
61 |
GND |
" |
" |
" |
" |
" |
" |
" |
18 to 1Y |
" |
" |
" |
" |
" |
" |
" |
|||
" |
" |
120 |
" |
GND |
61 |
51 |
" |
" |
" |
" |
" |
" |
" |
2A to 2Y |
" |
" |
" |
" |
" |
" |
" |
|||
" |
" |
121 |
" |
" |
61 |
GND |
51 |
" |
" |
" |
" |
" |
" |
28 to 2Y |
" |
" |
" |
" |
" |
" |
" |
|||
" |
" |
122 |
" |
" |
" |
GND |
" |
51 |
" |
61 |
" |
" |
" |
3A to 3Y |
" |
" |
" |
" |
" |
" |
" |
|||
" |
" |
123 |
" |
" |
" |
" |
" |
GND |
51 |
61 |
" |
" |
" |
38 to 3Y |
" |
" |
" |
" |
" |
" |
" |
|||
" |
" |
124 |
" |
" |
" |
" |
" |
" |
GND |
61 |
51 |
" |
" |
4A to 4Y |
" |
" |
" |
" |
" |
" |
" |
|||
" |
" |
125 |
" |
" |
" |
" |
" |
" |
" |
61 |
GND |
51 |
" |
48 to 4Y |
" |
" |
" |
" |
" |
" |
" |
|||
tPLH |
3003 |
126 |
51 |
" |
61 |
" |
" |
" |
" |
" |
" |
GND |
" |
1A to 1Y |
13 |
210 |
18 |
315 |
13 |
210 |
" |
|||
" |
Fig. 3 |
127 |
GND |
51 |
61 |
" |
" |
" |
" |
" |
" |
" |
" |
18 to 1Y |
" |
" |
" |
" |
" |
" |
" |
|||
" |
" |
128 |
" |
GND |
61 |
51 |
" |
" |
" |
" |
" |
" |
" |
2A to 2Y |
" |
" |
" |
" |
" |
" |
" |
|||
" |
" |
129 |
" |
" |
61 |
GND |
51 |
" |
" |
" |
" |
" |
" |
28 to 2Y |
" |
" |
" |
" |
" |
" |
" |
|||
" |
" |
130 |
" |
" |
" |
GND |
" |
51 |
" |
61 |
" |
" |
" |
3A to 3Y |
" |
" |
" |
" |
" |
" |
" |
|||
" |
" |
131 |
" |
" |
" |
" |
" |
GND |
51 |
61 |
" |
" |
" |
38 to 3Y |
" |
" |
" |
" |
" |
" |
" |
|||
" |
" |
132 |
" |
" |
" |
" |
" |
" |
GND |
61 |
51 |
" |
" |
4A to 4Y |
" |
" |
" |
" |
" |
" |
" |
|||
" |
" |
133 |
" |
" |
" |
" |
" |
" |
" |
61 |
GND |
51 |
" |
48 to 4Y |
" |
" |
" |
" |
" |
" |
" |
See notes at end of device type 54.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business