TA8LE III. Group A inspection for device type 02. Continued
Terminal conditions (pins not designated may be H > 2.0 v or L < 0.8 v or open).
Subgroup |
Symbol |
MIL- STD-883 method |
Cases A,8,D |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
Measured terminal |
Test limits |
||
Case C |
11 |
12 |
1 |
14 |
13 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
Min |
Max |
Unit |
||||
Test no. |
NC |
NC |
1A |
vCC |
18 |
2A |
28 |
2C |
2D |
2Y |
GND |
1Y |
1C |
1D |
|||||||
1 TC = +25°C " " " " " ’‘ " " " " " " " " |
IOS |
3011 |
37 |
GND |
5.5 v |
GND |
GND |
GND |
GND |
GND |
1Y |
-20 |
-55 |
mA |
|||||||
IOS |
3011 |
38 |
" |
GND |
GND |
GND |
GND |
GND |
" |
2Y |
-20 |
-55 |
" |
||||||||
ICCL |
3005 |
39 |
5.5 v |
" |
5.5 v |
5.5 v |
5.5 v |
5.5 v |
5.5 v |
" |
5.5 v |
5.5 v |
vCC |
14 |
" |
||||||
ICCH |
3005 |
40 |
GND |
" |
GND |
GND |
GND |
GND |
GND |
" |
GND |
GND |
vCC |
7.2 |
" |
||||||
vIC " " " " " " " |
41 42 43 44 45 46 47 48 |
-12 mA |
4.5 v " " " " " " " |
-12 mA |
-12 mA |
-12 mA |
-12 mA |
-12 mA |
" " " " " " " " |
-12 mA |
12 mA |
1A 18 1C 1D 2A 28 2C 2D |
-1.5 " " " " " " " |
v " " " " " " " |
|||||||
2 |
Same tests, terminal conditions and limits as for subgroup 1, except TC = +125°C and vIC tests are omitted. |
||||||||||||||||||||
3 |
Same tests, terminal conditions and limits as for subgroup 1, except TC = -55°C and vIC tests are omitted. |
||||||||||||||||||||
9 |
tPHL |
3003 (Fig 3) |
49 50 |
IN GND |
5.0 v " |
2.4 v GND |
GND IN |
GND 2.4 v |
GND " |
GND " |
OUT |
GND |
OUT |
GND " |
GND " |
1A to 1Y 2A to 2Y |
3 " |
20 20 |
ns " |
||
tPLH |
" |
51 52 |
IN GND |
" " |
2.4 v GND |
GND IN |
GND 2.4 v |
" " |
" " |
OUT |
" " |
OUT |
" " |
" " |
1A to 1Y 2A to 2Y |
" " |
27 27 |
" " |
|||
10 TC = +125°C |
tPHL |
" |
53 54 |
IN GND |
" " |
2.4 v GND |
GND IN |
GND 2.4 v |
" " |
" " |
OUT |
" " |
OUT |
" " |
" " |
1A to 1Y 2A to 2Y |
" " |
24 24 |
" " |
||
tPLH |
" |
55 56 |
IN GND |
" " |
2.4 v GND |
GND IN |
GND 2.4 v |
" " |
" " |
OUT |
" " |
OUT |
" " |
" " |
1A to 1Y 2A to 2Y |
" " |
30 30 |
" " |
|||
11 |
Same tests, terminal conditions and limits as for subgroup 10, except TC = -55°C. |