TA8LE III. Group A inspection for device type 01. - Continued
Terminal conditions (High > 2.0 V, Low < 0.8 V or open).
Subgroup |
Symbol |
MIL- STD-883 method |
Cases A, 8, D |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
Meas. terminal |
Test limits |
||
Case C |
11 |
12 |
1 |
14 |
13 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
Min |
Max |
Unit |
||||
Test no. |
x |
x |
1A |
VCC |
18 |
2A |
28 |
2C |
2D |
2Y |
GND |
1Y |
1C |
1D |
|||||||
1 TC = +25°C " " " " '‘ " " " " " " " " " " " " " " " " " |
IIH2 " " " " " " " |
3010 " " " " " " " |
31 32 33 34 35 36 37 38 |
5.5 V GND |
5.5 V " " " " " " " |
GND 5.5 V |
5.5 V GND |
GND 5.5 V |
5.5 V GND |
GND 5.5 V |
GND " " " " " " " |
5.5 V GND |
GND 5.5 V |
1A 18 2A 28 2C 2D 1C 1D |
100 " " " " " " " |
mA " " " " " " " |
|||||
IOS |
3011 |
39 |
GND |
" |
GND |
" |
GND |
GND |
GND |
1Y |
-20 |
-55 |
mA |
||||||||
IOS |
3011 |
40 |
" |
GND |
GND |
GND |
GND |
GND |
" |
2Y |
-20 |
-55 |
" |
||||||||
ICCL |
3005 |
41 |
5.5 V |
" |
5.5 V |
5.5 V |
5.5 V |
5.5 V |
5.5 V |
" |
5.5 V |
5.5 V |
VCC |
14 |
" |
||||||
ICCH |
3005 |
42 |
GND |
" |
GND |
GND |
GND |
GND |
GND |
" |
GND |
GND |
VCC |
7.2 |
" |
||||||
VIC " " " " " " " |
43 44 45 46 47 48 49 50 |
-12 mA |
4.5 V " " " " " " " |
-12 mA |
-12 mA |
-12 mA |
-12 mA |
-12 mA |
" " " " " " " " |
-12 mA |
-12 mA |
1A 18 1C 1D 2A 28 2C 2D |
-1.5 " " " " " " " |
V " " " " " " " |
|||||||
Ix Ix Vx V8E |
31 31 31 21 |
51 51a 51b 52 |
-.4 V 1.7 mA .41 mA |
11 1.4 V 0.8 V |
GND " " " |
" " " " |
GND " " " |
GND " " " |
GND " " " |
GND " " " |
" " " " |
16 mA 16 mA 16 mA 16 mA |
GND " " " |
GND " " " |
x x x x |
0.62 |
-2.9 mA -2.58 mA 1.1 |
mA mA V V |
|||
2 Same tests, terminal conditions and limits as for subgroup 1, except TC = +125°C and VIC tests are omitted. |
|||||||||||||||||||||
3 Same tests, terminal conditions and limits as for subgroup 1, except TC = -55°C and VIC tests are omitted. |
|||||||||||||||||||||
9 |
tPHL |
3003 (Fig 3) |
53 54 |
IN GND |
5.0 V " |
2.4 V GND |
GND IN |
GND 2.4 V |
GND " |
GND " |
OUT |
GND |
OUT |
GND " |
GND " |
1A to 1Y 2A to 2Y |
3 3 |
20 20 |
ns " |
||
tPLH |
" |
55 56 |
IN GND |
" " |
2.4 V GND |
GND IN |
GND 2.4 V |
" " |
" " |
OUT |
" |
OUT |
" " |
" " |
1A to 1Y 2A to 2Y |
3 3 |
27 27 |
" " |
|||
10 TC = +125°C |
tPHL |
" |
57 58 |
IN GND |
" " |
2.4 V GND |
GND IN |
GND 2.4 V |
" " |
" " |
OUT |
" |
OUT |
" " |
" " |
1A to 1Y 2A to 2Y |
3 3 |
24 24 |
" " |
||
tPLH |
" |
59 60 |
IN GND |
" " |
2.4 V GND |
GND IN |
GND 2.4 V |
" " |
" " |
OUT |
" |
OUT |
" " |
" " |
1A to 1Y 2A to 2Y |
3 3 |
30 30 |
" " |
|||
11 |
Same tests, terminal conditions and limits as for subgroup 10, except TC = -55°C. |
NOTES: 11 -.4 V at x referenced to x (see figure 4).
21 x and x shorted (see figure 5).
31 At the manufacturer's option, the expander current test may be verified by performing either 51 or 51a and 51b.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business