TABLE III. Group A inspection for device type 02.
Terminal conditions (pins not designated may be high � 2.0 V; low s 0.8 V; or open).
1/ For case 2, pins not referenced are NC.
2/ Apply all voltages, then apply 3.0 V, 0.0 V, 3.0 V to CP then make measurement.
3/ Perform function sequence at VCC = 4.5 V and repeat at VCC = 5.5 V.
4/ A = 3.0 V, B = 0.0 V or GND; H > 1.5 V, L < 1.5 V.
5/ IIL limits (mA) min/max values for circuit shown:
Test |
Min/Max limits in mA |
||
CKT A |
B |
C |
|
IIL |
-.25/-.60 |
-.03/-.60 |
6/ fMAX shall be measured only under the conditions of initial qualification and after process or design changes which may affect this parameter.
For all other conditions, fMAX shall be guaranteed, if not tested, to the imits specified in table III, herein.