MIL-M-38510/3438
Device types 01 and 02
Mode select table
* SR |
PE |
CET |
CEP |
Action on the rising clock edge ( ‗ ) |
L |
x |
x |
x |
Reset (clear) |
H |
L |
x |
x |
Load (Pn - Qn) |
H |
H |
H |
H |
Count (increment) |
H |
H |
L |
x |
No change (hold) |
H |
H |
x |
L |
No change (hold) |
* For F163A only
H = High voltage level
L = Low voltage level x = Immaterial
Device type 03
Mode select table RC truth table
Inputs |
Mode |
|||
PL |
CE |
U / D |
CP |
|
H |
L |
L |
‗ |
Count up |
H |
L |
H |
‗ |
Count down |
L |
x |
x |
x |
Preset (asyn) |
H |
H |
x |
x |
No change (hold) |
*TC is generated internally
H = High voltage level
L = Low voltage level x = Immaterial
‗ = Transition from low to high level
‗ = One low level pulse
Device type 04
Function table
MR |
PL |
CPU |
CPD |
Mode |
H |
x |
x |
x |
Reset (asyn) |
L |
L |
x |
x |
Preset (asyn) |
L |
H |
H |
H |
No change |
L |
H |
‗ |
H |
Count up |
L |
H |
H |
‗ |
Count down |
H = High voltage level L = Low voltage level x = Immaterial
‗ = Transition from low to high level
FIGURE 3. Truth table.
14
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business