MlL-M-38510/327B
1/ Apply
2/ Apply
┌──┐
┘ └
┌──┐
┘ └
- - 2.0 V min./5.5 V max. prior to test after clear pulse.
0.0 ±0.2 V
- - 2.0 V min./5.5 V max. pulse prior to test.
0.0 ±0.2 V
3/ Apply 2 pulses after clear pulse (see 1/).
4/ Apply 4 pulses after clear pulse (see 1/).
5/ llL limits shall be as follows:
Symbol |
Min/Max limits (mA) |
||
Circuit |
|||
A |
E |
B |
|
llL1 (CLR) |
-.15/-.38 |
-.135/-.37 |
-.16/-.40 |
llL2 (ST9) |
-.16/-.40 |
-.135/-.37 |
-.16/-.40 |
llL3 |
-.35/-1.6 |
-1.0/-2.4 |
-.35/-1.6 |
6/ Only a summary of attributes data is required.
7/ A = 2.4 V min. and B = 0.4 V max.
8/ Output voltages shall be either:
a. H � 2.5 V and L ≤ 0.4 V when using a high speed double comparator, or b. H � 1.5 V and L ≤ 1.5 V when using a high speed single comparator.
9/ FMAX1 minimum limits specified is the frequency of the input pulse. The output pulse shall be one half the input frequency.
10/ Apply sufficient
┌──┐
┘ └
- - 2.0 V min./5.5 V max. pulses to set output high prior to test.
0.0 ±0.2 V