MIL-M-38510/3230
NOTES:
1. CL = 50 pF ±10% minimum for all tests. CL includes scope probe and jig capacitance.
2. Waveform 1 is for an output with internal conditions such that the output is low except when disabled by the
output control.
Waveform 2 is for an output with internal conditions such that the output is high except when disabled by the output control.
3. In the examples above, the phase relationships between inputs and outputs have been chosen arbitrarily.
4. All input pulses are supplied by generators having the following characteristics: PRR � 1 MHz, tp = 500 ns, ZOUT ≈ 50n, Vgen = 3.0 V, tr � 15 ns, tf � 6 ns between 0.7 V and 2.7 V.
FIGURE 3. Switching time test circuit and waveforms.