TABLE III. Group A inspection for device type 04.
Terminal conditions (pins not designated may be high � 2.0 V; low s 0.7 V; or open).
Subgroup |
Symbol |
MIL-STD- 883 method |
Cases E, F |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
Measured terminal |
Limits |
Unit |
|
Cases 2, x 5/ |
2 |
3 |
4 |
5 |
7 |
8 |
9 |
10 |
12 |
13 |
14 |
15 |
17 |
18 |
19 |
20 |
|||||||
Test no. |
E 1 |
1A |
1Y |
2A |
2Y |
3A |
3Y |
GND |
4Y |
4A |
5Y |
5A |
6Y |
6A |
E 2 |
VCC |
Min |
Max |
|||||
10 TC =125°C |
tPLH |
3003 Fig. 3 " " " " |
92 |
GND |
3/ |
OUT |
GND |
5.0 V |
1A - 1Y |
2 |
20 |
ns |
|||||||||||
93 |
" |
3/ |
OUT |
" |
" |
2A - 2Y |
" |
" |
" |
||||||||||||||
94 |
" |
3/ |
OUT |
" |
" |
3A - 3Y |
" |
" |
" |
||||||||||||||
95 |
" |
" |
OUT |
3/ |
" |
4A - 4Y |
" |
" |
" |
||||||||||||||
96 |
" |
OUT |
3/ |
GND |
" |
5A - 5Y |
" |
" |
" |
||||||||||||||
97 |
" |
OUT |
3/ |
GND |
" |
6A - 6Y |
" |
" |
" |
||||||||||||||
tPHL |
" " " " " " |
98 |
GND |
3/ |
OUT |
" |
" |
1A - 1Y |
" |
23 |
" |
||||||||||||
99 |
" |
3/ |
OUT |
" |
" |
2A - 2Y |
" |
" |
" |
||||||||||||||
100 |
" |
3/ |
OUT |
" |
" |
3A - 3Y |
" |
" |
" |
||||||||||||||
101 |
" |
" |
OUT |
3/ |
" |
4A - 4Y |
" |
" |
" |
||||||||||||||
102 |
" |
OUT |
3/ |
GND |
" |
5A - 5Y |
" |
" |
" |
||||||||||||||
103 |
" |
OUT |
3/ |
GND |
" |
6A - 6Y |
" |
" |
" |
||||||||||||||
tPZH |
" |
104 |
4/ |
GND |
OUT |
" |
" |
E 1 - 1Y |
" |
45 |
" |
||||||||||||
tPZL |
" |
105 |
4/ |
4.5 V |
" |
" |
" |
E 1 - 1Y |
" |
58 |
" |
||||||||||||
tPHZ |
" |
106 |
4/ |
GND |
" |
" |
" |
E 1 - 1Y |
" |
42 |
" |
||||||||||||
tPLZ |
" |
107 |
4/ |
4.5 V |
" |
" |
" |
E 1 - 1Y |
" |
45 |
" |
||||||||||||
11 |
Same tests, terminal conditions and limits as for subgroup 10, except TC = -55°C. |
1/ IIL limits (µA) min/max values for circuits are shown below.
2/ IOS limits (mA) min/max values for circuits are shown below.
Parameter |
Terminals |
Circuits |
|||||
A |
B |
C |
D |
E |
F |
||
IIL1 |
1A, 2A, 3A, 4A, 5A, 6A |
-150/-380 |
-30/-300 |
-160/-400 |
-160/-400 |
-160/-400 |
-150/-380 |
IIL2 |
E 1, E 2 |
-1.0/-150 |
-30/-300 |
-160/-400 |
-160/-400 |
-160/-400 |
-150/-380 |
IOS |
1Y, 2Y, 3Y, 4Y, 5Y, 6Y |
-40/-225 |
-30/-130 |
-40/-225 |
-15/-100 |
-30/-130 |
-15/-100 |
3/ Pulse from input pulse generator.
4/ Pulse from disable generator.
5/ For cases 2 and x, pins not referenced are NC.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business