TABLE III. Group A inspection for device type 01 - Continued.
Terminal conditions (pins not designated may be high � 2.0 V; low s 0.7 V; or open).
1/ IIL limits (µA) min/max values for circuits are shown below.
2/ IOS limits (mA) min/max values for circuits are shown below.
Parameter |
Terminals |
Circuits |
|||||
A |
B |
C |
D |
E |
F |
||
IIL1 |
1A, 2A, 3A, 4A, 5A, 6A |
-150/-380 |
-30/-300 |
-160/-400 |
-160/-400 |
-160/-400 |
0/-200 |
IIL2 |
E 1, E 2 |
-1.0/-150 |
-30/-300 |
-160/-400 |
-160/-400 |
-160/-400 |
-150/-380 |
IOS |
1Y, 2Y, 3Y, 4Y, 5Y, 6Y |
-40/-225 |
-30/-130 |
-40/-225 |
-15/-100 |
-30/-130 |
-15/-100 |
3/ Pulse from input pulse generator.
4/ Pulse from disable generator.
5/ For cases 2 and x, pins not referenced are NC.