TABLE lll. Group A inspection for device type 02.
Terminal conditions (pins not designated may be high � 2.0 V; low s 0.7 V; or open).
1/ Min/max limits (µA) for circuits, unless otherwise specified.
Test |
Min/max limits (mA) |
||||
A |
B |
C |
E |
F |
|
llL1 |
-120/-360 |
-30/-300 |
-160/-400 except -120/-360 for test 24 |
-120/-360 except -0.5/-360 for tests 22 and 24 |
-135/-370 except -150/-380 for test 23 |
llL2 |
-240/-720 |
-90/-900 |
-305/-760 |
-240/-720 |
-320/-800 |
llL3 |
-240/-720 |
-60/-600 |
-305/-760 |
-240/-720 |
-320/-800 |
2/ Connect a 0.5 kn to 2 kn resistor from terminals, 6, 7, 9, and 10 to VCC for subgroup 7 tests.
3/ A = 3.0 V min., B = 0.0 V or GND, C = pulse 3.0 V ─┐ ┌─ 3.0 V
0.0 V └──┘
4/ Output voltages shall be: H > 1.5 V, L < 1.5 V
5/ Load ground into register under test prior to test.
6/ Load one state into register under test prior to test.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business