MIL-M-38510/319C
NOTES:
1. Input pulse characteristics: PRR ≤ 1.0 MHz, tr ≤ 15 ns, tf ≤ 6 ns, duty cycle = 50% ±15%.
2. CL = 50 pF ±10%. CL includes probe and jig capacitance.
3. All diodes are 1N3064 and 1N916.
4. Load circuits on a given output are required only where the specific test given in table III indicates "OUT" on that output. Load circuits may otherwise be omitted.
FIGURE 4. Switching test circuit and waveforms for device types 01 and 02.