TABLE III. Group A inspection for device type 09 - Continued.
Terminal conditions (pins not designated may be high 2.0 V; low σ 0.7 V; or open).
Subgroup |
Symbol |
MIL-STD- 883 method |
Cases E, F |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
Measured terminal |
Limits |
Unit |
|
Cases 1/ 2, X |
2 |
3 |
4 |
5 |
7 |
8 |
9 |
10 |
12 |
13 |
14 |
15 |
17 |
18 |
19 |
20 |
|||||||
Test no. |
B2 |
A2 |
A1 |
B1 |
C2 |
D2 |
D1 |
GND |
C1 |
wS |
CP |
QD |
QC |
QB |
QA |
VCC |
Min |
Max |
|||||
2 |
Same tests, terminal conditions and limits as subgroup 1, except TC = +125°C and VI C tests omitted. |
||||||||||||||||||||||
3 |
Same tests, terminal conditions and limits as subgroup 1, except TC = -55°C and VI C tests omitted. |
||||||||||||||||||||||
7 Tc = 25°C |
Func- tional tests |
3014 |
54 |
A |
A |
B |
B |
A |
A |
B |
GND |
B |
B |
A |
L |
L |
L |
L |
5.0 V |
All |
|||
" |
55 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
B |
" |
" |
" |
" |
" |
ouputs |
|||||
" |
56 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
A |
" |
" |
" |
" |
" |
" |
|||||
" |
57 |
" |
" |
A |
A |
" |
" |
A |
" |
A |
" |
A |
" |
" |
" |
" |
" |
" |
|||||
" |
58 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
B |
H |
H |
H |
H |
" |
" |
|||||
" |
59 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
A |
" |
" |
" |
" |
" |
" |
|||||
" |
60 |
" |
" |
B |
B |
" |
" |
B |
" |
B |
" |
A |
" |
" |
" |
" |
" |
" |
|||||
" |
61 |
" |
" |
B |
B |
" |
" |
B |
" |
B |
" |
B |
L |
L |
L |
L |
" |
" |
|||||
" |
62 |
" |
" |
A |
A |
" |
" |
A |
" |
A |
" |
" |
" |
" |
" |
" |
" |
" |
5/ |
||||
" |
63 |
" |
" |
B |
B |
" |
" |
B |
" |
B |
" |
" |
" |
" |
" |
" |
" |
" |
|||||
" |
64 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
A |
" |
" |
" |
" |
" |
" |
|||||
" |
65 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
A |
" |
" |
" |
" |
" |
" |
" |
|||||
" |
66 |
" |
" |
A |
A |
" |
" |
A |
" |
A |
" |
" |
" |
" |
" |
" |
" |
" |
|||||
" |
67 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
B |
H |
H |
H |
H |
" |
" |
|||||
" |
68 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
A |
" |
" |
" |
" |
" |
" |
|||||
" |
69 |
B |
B |
" |
" |
B |
B |
" |
" |
" |
" |
A |
" |
" |
" |
" |
" |
" |
|||||
" |
70 |
B |
B |
" |
" |
B |
B |
" |
" |
" |
" |
B |
L |
L |
L |
L |
" |
" |
|||||
" |
71 |
A |
A |
" |
" |
A |
A |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
|||||
" |
72 |
B |
B |
" |
" |
B |
B |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
|||||
8 |
Repeat subgroup 7 tests at TC = +125°C and TC = -55°C. |
||||||||||||||||||||||
9 Tc = 25°C |
tPLH1 |
3003 |
73 |
IN |
GND |
5.5 V |
IN |
OUT |
5.0 V |
CP to QA |
3 |
33 |
ns |
||||||||||
Fig. 4 |
74 |
IN |
" |
" |
" |
OUT |
" |
CP to QB |
" |
" |
" |
||||||||||||
" |
75 |
IN |
" |
" |
" |
OUT |
" |
CP to QC |
" |
" |
" |
||||||||||||
" |
76 |
IN |
" |
" |
" |
OUT |
" |
CP to QD |
" |
" |
" |
||||||||||||
tPHL1 |
" |
77 |
IN |
" |
" |
" |
OUT |
" |
CP to QA |
" |
37 |
" |
|||||||||||
" |
78 |
IN |
" |
" |
" |
OUT |
" |
CP to QB |
" |
" |
" |
||||||||||||
" |
79 |
IN |
" |
" |
" |
OUT |
" |
CP to QC |
" |
" |
" |
||||||||||||
" |
80 |
IN |
" |
" |
" |
OUT |
" |
CP to QD |
" |
" |
" |
||||||||||||
10 |
Same tests, terminal conditions and limits as subgroup 9, except TC = +125°C and limits as follows: tPLH1 = 3 to 43 ns; tPHL1 = 3 to 48 ns. |
||||||||||||||||||||||
11 |
Same tests, terminal conditions and limits as subgroup 10, except TC = -55°C. |
1/ Case X and 2 pins not referenced are NC.
2/ Apply normal clock pulse.
3/ IIL limits shall be as follows:
Test |
Min/Max limits (mA) for circuits |
||||||
A |
B |
C |
D |
E |
F |
G |
|
IIL1 |
-.16/-.40 |
- |
- |
-.16/-.40 except -.03/-.30 test 27 and 28 |
-.16/-.40 except -.12/-.36 test 27 and 28 |
-.12/-.36 |
- |
4/ Apply 3.0 V pulse, then ground, then measure.
5/ Inputs: A 2.5 V minimum, B σ 0.4 V maximum.
Outputs: H 1.5 volts, L σ 1.5.