MIL-M-38510/309E
TABLE I. Electrical performance characteristics - Continued.
Test |
Symbol |
Conditions -55°C = TC = +125°C unless otherwise specified |
Device types |
Limits |
Unit |
|
Min |
Max |
|||||
Propagation delay time, low to high level output from select to W |
tPLH6 |
VCC = 5.0 V, CL = 50 pF ±10% RL = See figure 5. |
01 |
3 |
42 |
ns |
05 |
3 |
57 |
||||
Propagation delay time, high to low level output from select to W |
tPHL6 |
01 |
3 |
56 |
ns |
|
05 |
3 |
57 |
||||
Enable time to high level output from strobe to Y |
tPZH1 |
05 |
3 |
75 |
ns |
|
Enable time to high level output from strobe to W |
tPZH2 |
05 |
3 |
48 |
ns |
|
Enable time to high level output from output control to Y |
tPZH3 |
06, 07 |
3 |
53 |
ns |
|
08 |
3 |
69 |
||||
Enable time to low level output from strobe to Y |
tPZL1 |
05 |
3 |
68 |
ns |
|
Enable time to low level output from strobe to W |
tPZL2 |
05 |
3 |
68 |
ns |
|
Enable time to low level output from output control to Y |
tPZL3 |
06, 07 |
3 |
53 |
ns |
|
08 |
3 |
42 |
||||
Disable time from high level output, from strobe to Y |
tPHZ1 |
VCC = 5.0 V, CL = 15 pF minimum RL = See figure 5. |
05 |
3 |
75 |
ns |
Disable time from high level output, from strobe to W |
tPHZ2 |
05 |
3 |
90 |
ns |
|
Disable time from high level output, from output control to Y |
tPHZ3 |
06, 07 |
3 |
53 |
ns |
|
08 |
3 |
69 |
||||
Disable time from low level output, from strobe to Y |
tPLZ1 |
05 |
3 |
45 |
ns |
|
Disable time from low level output, from strobe to W |
tPLZ2 |
05 |
3 |
45 |
ns |
|
Disable time from low level output, from output control to Y |
tPLZ3 |
06, 07 |
3 |
45 |
ns |
|
08 |
3 |
48 |
8