TABLE III. Group A inspection for device type 01 - Continued.
Terminal conditions (pins not designated may be high � 2.0 V; low s 0.7 V; or open).
Subgroup |
Symbol |
MIL-STD- 883 method |
Cases J, K, Z |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
Measured terminal |
Limits |
Unit |
|
Case 3 1/ |
2 |
3 |
4 |
5 |
6 |
7 |
9 |
10 |
11 |
12 |
13 |
14 |
|||||||
Test no. |
B 0 |
A 0 |
S3 |
S2 |
S1 |
S0 |
Cn |
M |
F 0 |
F 1 |
F 2 |
GND |
Min |
Max |
|||||
9 Tc = 25°C |
tPHL13 |
3003 Fig 4 " " " " " " |
271 |
GND |
IN |
GND |
4.5 V |
4.5 V |
GND |
GND |
4.5 V |
OUT |
GND |
A 0 to F 0 |
2 |
38 |
ns |
||
272 |
" |
GND |
" |
" |
" |
" |
" |
" |
OUT |
" |
A 1 to F 1 |
" |
" |
" |
|||||
273 |
" |
" |
" |
" |
" |
" |
" |
" |
OUT |
" |
A 2 to F 2 |
" |
" |
" |
|||||
274 |
" |
" |
" |
" |
" |
" |
" |
" |
OUT |
" |
A 3 to F 3 |
" |
" |
" |
|||||
275 |
IN |
" |
" |
" |
" |
" |
" |
" |
OUT |
" |
B 0 to F 0 |
" |
" |
" |
|||||
276 |
GND |
" |
" |
" |
" |
" |
" |
" |
OUT |
" |
B 1 to F 1 |
" |
" |
" |
|||||
277 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
B 2 to F 2 |
" |
" |
" |
||||||
278 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
B 3 to F 3 |
" |
" |
" |
||||||
tPLH13 |
" " " " " " " " |
279 |
" |
IN |
" |
" |
" |
" |
" |
" |
OUT |
" |
A 0 to F 0 |
" |
33 |
" |
|||
280 |
" |
GND |
" |
" |
" |
" |
" |
" |
OUT |
" |
A 1 to F 1 |
" |
" |
" |
|||||
281 |
" |
" |
" |
" |
" |
" |
" |
" |
OUT |
" |
A 2 to F 2 |
" |
" |
" |
|||||
282 |
" |
" |
" |
" |
" |
" |
" |
" |
OUT |
" |
A 3 to F 3 |
" |
" |
" |
|||||
283 |
IN |
" |
" |
" |
" |
" |
" |
" |
OUT |
" |
B 0 to F 0 |
" |
" |
" |
|||||
284 |
GND |
" |
" |
" |
" |
" |
" |
" |
OUT |
" |
B 1 to F 1 |
" |
" |
" |
|||||
285 |
GND |
" |
" |
" |
" |
" |
" |
" |
" |
B 2 to F 2 |
" |
" |
" |
||||||
286 |
GND |
" |
" |
" |
" |
" |
" |
" |
" |
B 3 to F 3 |
" |
" |
" |
||||||
10 |
Same tests and terminal conditions as subgroup 9, except Tc = 125°C and limits as follows: tPHL1 = 2 to 37 ns; tPLH1 = 2 to 55 ns; tPHL8 = 2 to 96 ns; tPLH8 = 2 to 100 ns; tPHL2 and tPLH2 = 2 to 55 ns; tPHL9 = 2 to 37 ns; tPLH9 = 2 to 48 ns; tPHL3 and tPLH3 = 2 to 52 ns; tPHL10 = 2 to 37 ns; tPLH10 = 2 to 48 ns; tPHL4 = 2 to 57 ns; tPLH4 = 2 to 52 ns; tPHL11 and tPLH11 = 2 to 64 ns; tPHL5 = 2 to 42 ns; tPLH5 = 2 to 51 ns; tPHL12 = 2 to 60 ns; tPLH12 = 2 to 69 ns; tPHL6 and tPLH6 = 2 to 55 ns; tPHL13 = 2 to 48 ns; tPLH13 = 2 to 57 ns; tPHL7 = 2 to 37 ns; tPLH7 = 2 to 46 ns; |
||||||||||||||||||
11 |
Same tests, terminal conditions and limits as subgroup 10, except Tc = -55°C |
See footnotes at end of table. Pins 13 thru 24 on next page.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business