TABLE III. Group A inspection for device type 02 - Continued. 1/
Subgroup |
Symbol |
MIL-STD- 883 method |
Cases E, F |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
Measured terminal |
Limits |
Unit |
|
Cases 1/ 2, X |
2 |
3 |
4 |
5 |
7 |
8 |
9 |
10 |
12 |
13 |
14 |
15 |
17 |
18 |
19 |
20 |
|||||||
Test no. |
1G |
1A |
1B |
1Y0 |
1Y1 |
1Y2 |
1Y3 |
GND |
2Y3 |
3Y2 |
2Y1 |
2Y0 |
2B |
2A |
2G |
VCC |
Min |
Max |
|||||
7 3/ Tc = 25°C |
Truth table tests |
3014 " " " " " " " |
50 |
A |
A |
A |
H |
H |
H |
H |
GND |
H |
H |
H |
H |
A |
A |
A |
5.0 V |
3/ |
|||
51 |
" |
B |
A |
" |
" |
" |
" |
" |
" |
" |
" |
" |
A |
B |
" |
" |
|||||||
52 |
" |
A |
B |
" |
" |
" |
" |
" |
" |
" |
" |
" |
B |
A |
" |
" |
|||||||
53 |
" |
B |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
B |
" |
" |
|||||||
54 |
B |
B |
" |
L |
" |
" |
" |
" |
" |
" |
" |
L |
" |
B |
B |
" |
|||||||
55 |
" |
A |
" |
H |
L |
" |
" |
" |
" |
" |
L |
H |
" |
A |
" |
" |
|||||||
56 |
" |
B |
A |
" |
H |
L |
" |
" |
" |
L |
H |
" |
A |
B |
" |
" |
|||||||
57 |
" |
A |
A |
" |
H |
H |
L |
" |
L |
H |
H |
" |
A |
A |
" |
" |
|||||||
8 3/ |
Truth table test |
3014 |
58 thru 65 |
Same tests as subgroup 7, except TC = +125°C |
|||||||||||||||||||
Truth table test |
3014 |
66 thru 73 |
Same tests as subgroup 7, except TC = -55°C |
||||||||||||||||||||
9 Tc = 25°C |
tPLH3 tPHL3 |
3003 Fig. 3 " " |
74 & 75 |
IN |
GND |
GND |
OUT |
GND |
5.0 V |
1G to 1Y0 |
5 |
29/37 |
ns |
||||||||||
76 & 77 |
" |
5.0 V |
GND |
OUT |
" |
" |
1G to 1Y1 |
" |
" |
" |
|||||||||||||
78 & 79 |
" |
GND |
5.0 V |
OUT |
" |
" |
1G to 1Y2 |
" |
" |
" |
|||||||||||||
80 & 81 |
" |
5.0 V |
5.0 V |
OUT |
" |
" |
1G to 1Y3 |
" |
" |
" |
|||||||||||||
tPLH2 tPHL2 |
" " " " |
82 & 83 |
GND |
IN |
GND |
OUT |
" |
" |
1A to 1Y0 |
" |
25/38 |
" |
|||||||||||
84 & 85 |
" |
IN |
5.0 V |
OUT |
" |
" |
1A to 1Y2 |
" |
" |
" |
|||||||||||||
86 & 87 |
" |
GND |
IN |
OUT |
" |
" |
1B to 1Y0 |
" |
" |
" |
|||||||||||||
88 & 89 |
" |
5.0 V |
IN |
OUT |
" |
" |
1B to 1Y1 |
" |
" |
" |
|||||||||||||
tPLH3 tPHL3 |
" " " " |
90 & 91 |
" |
OUT |
GND |
GND |
IN |
" |
2G to 2Y0 |
" |
29/37 |
" |
|||||||||||
92 & 93 |
" |
OUT |
GND |
5.0 V |
" |
" |
2G to 2Y1 |
" |
" |
" |
|||||||||||||
94 & 95 |
" |
OUT |
5.0 V |
GND |
" |
" |
2G to 2Y2 |
" |
" |
" |
|||||||||||||
96 & 97 |
" |
OUT |
5.0 V |
5.0 V |
" |
2G to 2Y3 |
" |
" |
" |
||||||||||||||
tPLH3 tPHL3 |
" " " " |
98 & 99 |
" |
OUT |
GND |
IN |
GND |
" |
2A to 2Y0 |
" |
25/38 |
" |
|||||||||||
100 & 101 |
" |
OUT |
5.0 V |
IN |
" |
" |
2A to 2Y2 |
" |
" |
" |
|||||||||||||
102 & 103 |
" |
OUT |
IN |
GND |
" |
" |
2B to 2Y0 |
" |
" |
" |
|||||||||||||
104 & 105 |
" |
OUT |
IN |
5.0 V |
" |
" |
2B to 2Y1 |
" |
" |
" |
|||||||||||||
tPLH4 tPHL4 |
" " " " " " " " |
106 & 107 |
GND |
IN |
GND |
OUT |
" |
" |
1A to 1Y1 |
" |
34/43 |
" |
|||||||||||
108 & 109 |
" |
IN |
5.0 V |
OUT |
" |
" |
1A to 1Y3 |
" |
" |
" |
|||||||||||||
110 & 111 |
" |
GND |
IN |
OUT |
" |
" |
1B to 1Y2 |
" |
" |
" |
|||||||||||||
112 & 113 |
" |
5.0 V |
IN |
OUT |
" |
" |
1B to 1Y3 |
" |
" |
" |
|||||||||||||
114 & 115 |
" |
OUT |
GND |
IN |
GND |
" |
2A to 2Y1 |
" |
" |
" |
|||||||||||||
116 & 117 |
" |
OUT |
5.0 V |
IN |
" |
" |
2A to 2Y3 |
" |
" |
" |
|||||||||||||
118 & 119 |
" |
OUT |
IN |
GND |
" |
" |
2B to 2Y2 |
" |
" |
" |
|||||||||||||
120 & 121 |
" |
OUT |
IN |
5.0 V |
" |
" |
2B to 2Y3 |
" |
" |
" |
|||||||||||||
10 |
Same tests and terminal conditions as for subgroup 9, except TC = +125°C and for following limits: tPLH2 = 5 to 38 ns; tPHL2 = 5 to 57 ns; tPLH3 = 5 to 44 ns; tPHL3 = 5 to 56 ns; tPLH4 = 5 to 51 ns; tPHL4 = 5 to 65 ns. |
||||||||||||||||||||||
11 |
Same tests, terminal conditions and limits as for subgroup 10, except TC = -55°C |
1/ Pins not designated are high 2.0 V; low σ 0.7 V; or open. Case X and 2 pins not referenced are NC.
2/ IIL1 limits are as follows:
IIL1 |
Min/Max limits (mA) for circuits |
|||
A, C, E, F |
B |
D |
G |
|
-.012/-.36 |
-.03/-.300 |
-.10/-.34 |
-.15/-.38 |
3/ H 1.5 V; L σ 1.5 V; A = 2.5 V; B = 0.4 V.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business