TABLE III. Group A inspection for device type 01 - Continued. 1/
Subgroup |
Symbol |
MIL-STD- 883 method |
Cases E, F |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
Measured terminal |
Limits |
Unit |
|
Cases 1/ 2, X |
2 |
3 |
4 |
5 |
7 |
8 |
9 |
10 |
12 |
13 |
14 |
15 |
17 |
18 |
19 |
20 |
|||||||
Test no. |
A |
B |
C |
G2A |
G2B |
G1 |
Y7 |
GND |
Y6 |
Y5 |
Y4 |
Y3 |
Y2 |
Y1 |
Y0 |
VCC |
Min |
Max |
|||||
9 Tc = 25°C |
tPLH4 tPHL4 |
3003 Fig. 3 " " " " " " " " " " |
157 &158 |
IN |
GND |
GND |
GND |
GND |
5.0 V |
GND |
OUT |
5.0 V |
A to Y1 |
5 |
32/54 |
ns |
|||||||
159 & 160 |
" |
5.0 V |
GND |
" |
" |
" |
" |
OUT |
" |
A to Y3 |
" |
" |
" |
||||||||||
161 & 162 |
" |
GND |
5.0 V |
" |
" |
" |
" |
OUT |
" |
A to Y5 |
" |
" |
" |
||||||||||
163 & 164 |
" |
5.0 V |
5.0 V |
" |
" |
" |
OUT |
" |
" |
A to Y7 |
" |
" |
" |
||||||||||
165 & 166 |
GND |
IN |
GND |
" |
" |
" |
" |
OUT |
" |
B to Y2 |
" |
" |
" |
||||||||||
167 & 168 |
5.0 V |
" |
GND |
" |
" |
" |
" |
OUT |
" |
B to Y3 |
" |
" |
" |
||||||||||
169 & 170 |
GND |
" |
5.0 V |
" |
" |
" |
" |
OUT |
" |
B to Y6 |
" |
" |
" |
||||||||||
171 & 172 |
5.0 V |
" |
5.0 V |
" |
" |
" |
OUT |
" |
" |
B to Y7 |
" |
" |
" |
||||||||||
173 & 174 |
GND |
GND |
IN |
" |
" |
" |
" |
OUT |
" |
C to Y4 |
" |
" |
" |
||||||||||
175 & 176 |
5.0 V |
GND |
" |
" |
" |
" |
" |
OUT |
" |
C to Y5 |
" |
" |
" |
||||||||||
177 & 178 |
GND |
5.0 V |
" |
" |
" |
" |
" |
OUT |
" |
C to Y6 |
" |
" |
" |
||||||||||
179 & 180 |
5.0 V |
5.0 V |
" |
" |
" |
" |
OUT |
" |
" |
C to Y7 |
" |
" |
" |
||||||||||
tPLH5 tPHL5 |
3003 Fig. 3 " " " " " " |
181 & 182 |
GND |
GND |
GND |
" |
" |
IN |
" |
OUT |
" |
G1 to Y0 |
" |
31/43 |
" |
||||||||
183 & 184 |
5.0 V |
GND |
" |
" |
" |
" |
" |
OUT |
" |
G1 to Y1 |
" |
" |
" |
||||||||||
185 & 186 |
GND |
5.0 V |
" |
" |
" |
" |
" |
OUT |
" |
G1 to Y2 |
" |
" |
" |
||||||||||
187 & 188 |
5.0 V |
5.0 V |
" |
" |
" |
" |
" |
OUT |
" |
G1 to Y3 |
" |
" |
" |
||||||||||
189 & 190 |
GND |
GND |
5.0 V |
" |
" |
" |
" |
OUT |
" |
G1 to Y4 |
" |
" |
" |
||||||||||
191 & 192 |
5.0 V |
GND |
" |
" |
" |
" |
" |
OUT |
" |
G1 to Y5 |
" |
" |
" |
||||||||||
193 & 194 |
GND |
5.0 V |
" |
" |
" |
" |
" |
OUT |
" |
G1 to Y6 |
" |
" |
" |
||||||||||
195 & 196 |
5.0 V |
5.0 V |
" |
" |
" |
" |
OUT |
" |
" |
G1 to Y7 |
" |
" |
" |
||||||||||
10 |
Same tests and terminal conditions as for subgroup 9, except TC = +125°C and for following limits: tPLH2 = 5 to 38 ns; tPHL2 = 5 to 69 ns; tPLH3 = 5 to 35 ns; tPHL3 = 5 to 56 ns; tPLH4 = 5 to 48 ns; tPHL4 = 5 to 81 ns; tPLH5 = 5 to 47 ns; tPHL5 = 5 to 65 ns. |
||||||||||||||||||||||
11 |
Same tests, terminal conditions and limits as for subgroup 10, except TC = -55°C. |
1/ Pins not designated are high 2.0 V; low σ 0.7 V; or open. Case X and 2 pins not referenced are NC.
2/ IIL1 limits are as follows:
IIL1 |
Min/Max limits (mA) for circuits |
||||
A |
B |
C, E, F |
D |
G |
|
-.001/-.150 except -.11/-.35 for tests 26, 27, 28 |
-.030/-.300 |
-.12/-.36 |
-.10/-.34 |
-.15/-.38 |
3/ A = 2.5 V and B = 0.4 V; H 1.5 V; L σ 1.5 V.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business