MIL-M-38510/3020
NOTES:
1. The pulse generator has the following characteristics: PRR ≤ 1 MHz, tTLH ≤ 15 ns, tTHL ≤ 6 ns, tP = 200 ns ±20 ns and ZOUT 50ν.
2. Including scope probe, wiring, and stray capacitance, without package in test fixture, CL = 125 pF ±10%.
3. Voltage measurements are to be made with respect to network ground terminal.
4. All diodes are 1N3064 or equivalent.
FIGURE 3. Switching time test circuit and waveforms for device types 01 and 02.
10
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business