TABLE III. Group A inspection for device type 01 - Continued.
Terminal conditions (pins not designated may be high � 2.0 V, low s 0.8 V, or open)
Subgroup |
Symbol |
MIL- STD- 883 method |
Cases J,K,Z |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
17 |
18 |
19 |
20 |
21 |
22 |
23 |
24 |
Measured terminal |
Limits |
Unit |
|
Test no. |
Y0 |
Y1 |
Y2 |
Y3 |
Y4 |
Y5 |
Y6 |
Y7 |
Y8 |
Y9 |
Y10 |
GND |
Y11 |
Y12 |
Y13 |
Y14 |
Y15 |
G1 |
G2 |
D |
C |
B |
A |
VCC |
Min |
Max |
|||||
10 TC=+125°C |
tPLH1 |
3003 (Fig 4) |
146 147 148 149 150 151 152 153 154 155 156 157 158 159 160 |
OUT |
OUT |
OUT |
OUT |
OUT |
OUT |
OUT |
OUT |
OUT |
OUT |
GND " " " " " " " " " " " " " " |
OUT |
OUT |
OUT |
OUT |
OUT |
GND " " " " " " " " " " " " " " |
GND " " " " " " " " " " " " " " |
GND " " " " " " IN " " " " 5.0V 5.0V IN |
GND " " IN " " 5.0V GND " " " 5.0V 5.0V IN 5.0V |
GND IN IN GND GND 5.0V 5.0V GND GND 5.0V 5.0V GND GND 5.0V 5.0V |
IN GND 5.0V GND 5.0V GND 5.0V GND 5.0V GND 5.0V GND IN GND 5.0V |
5.0V " " " " " " " " " " " " " " |
Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 Y10 Y11 Y12 Y13 Y14 Y15 |
5 " " " " " " " " " " " " " " |
53 " " " " " " " " " " " " " " |
ns " " " " " " " " " " " " " " |
|
tPHL2 |
161 162 |
OUT |
" " |
OUT |
IN GND |
" IN |
GND 5.0V |
GND 5.0V |
GND 5.0V |
GND 5.0V |
" " |
Y0 Y15 |
" " |
42 42 |
" " |
||||||||||||||||
tPLH2 |
163 164 165 166 167 168 |
OUT |
OUT |
OUT |
OUT |
OUT |
" " " " " " |
OUT |
IN GND " " " " |
GND IN GND " " " |
GND 5.0V GND " " IN |
GND 5.0V " " IN GND |
GND 5.0V GND IN 5.0V GND |
GND 5.0V IN GND 5.0V GND |
" " " " " " |
Y0 Y15 Y5 Y6 Y7 Y8 |
" " " " " " |
45 " " " " " |
" " " " " " |
||||||||||||
11 |
Same tests, terminal conditions, and limits as subgroup 10, except TC = -55°C. |
See footnote at end of table.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business