MIL-M-38510/152C
TABLE I. Electrical performance characteristics - Continued.
Test |
Symbol |
Conditions -55qC ≤ TC ≤ +125qC |
Device type |
Limits |
Unit |
|
Min |
Max |
|||||
Propagation delay time high-to-low level output A or B to output |
tPHL5 |
RL = 390 0 ± 5% CL = 50 pF minimum ± 10% (figure 6) |
03 |
3 |
57 |
ns |
Propagation delay time high-to-low level output A, B, C, or D to output through two levels |
tPHL1 |
RL = 390 0 ± 5% CL = 50 pF minimum ± 10% (figure 7) |
04,05, 06 |
5 |
48 |
ns |
Propagation delay time low-to-high level output A, B, C, or D to output through two levels |
tPLH1 |
04,05, 06 |
5 |
48 |
ns |
|
Propagation delay time high-to-low level output A, B, C, or D to output |
tPHL2 |
04,05, 06 |
5 |
53 |
ns |
|
Propagation delay time low-to-high level output A, B, C, or D to output |
tPLH2 |
04,05, 06 |
5 |
53 |
ns |
1/ Not more than one output should be shorted at one time.
TABLE II. Electrical test requirements.
MIL-PRF-38535 test requirements |
Subgroups (see table III) |
|
Class S devices |
Class B devices |
|
Interim electrical parameters |
1 |
1 |
Final electrical test parameters |
1*, 2, 3, 7, 9, 10, 11 |
1*, 2, 3, 7, 9 |
Group A test requirements |
1, 2, 3, 7, 8, 9, 10, 11 |
1, 2, 3, 7, 9, 10, 11 |
Group B electrical test parameters when using the method 5005 QCI option |
1,2,3,7,8,9, 10,11 |
N/A |
Group C end-point electrical parameters |
1,2,3,7,8,9, 10,11 |
1, 2, 3 |
Group D end-point electrical parameters |
1, 2, 3 |
1, 2, 3 |
*PDA applies to subgroup 1.
6
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business