MIL-M-3851011500
TABLE I. Electrical performance characteristics - Continued.
Test |
Symbol |
Conditions -55°C ≤ TC ≤ +125°C |
0evice type |
Limits |
Unit |
|
Min |
Max |
|||||
Propagation delay from A to A > B |
tPLH8 |
VCC = 5.0 V, RL = 390 n, CL = 50 pF |
02 |
3 |
30 |
ns |
Propagation delay from B to A > B |
tPLH9 |
VCC = 5.0 V, RL = 390 n, CL = 50 pF |
02 |
6 |
39 |
ns |
Propagation delay from E to A = B |
tPHL1 |
VCC = 5.0 V, RL = 390 n, CL = 50 pF |
02 |
3 |
19 |
ns |
Propagation delay from E to A < B |
tPHL2 |
VCC = 5.0 V, RL = 390 n, CL = 50 pF |
02 |
3 |
21 |
ns |
Propagation delay from E to A > B |
tPHL3 |
VCC = 5.0 V, RL = 390 n, CL = 50 pF |
02 |
3 |
21 |
ns |
Propagation delay from A to A = B |
tPHL4 |
VCC = 5.0 V, RL = 390 n, CL = 50 pF |
02 |
9 |
55 |
ns |
Propagation delay from B to A = B |
tPHL5 |
VCC = 5.0 V, RL = 390 n, CL = 50 pF |
02 |
9 |
55 |
ns |
Propagation delay time from A to A < B |
tPHL6 |
VCC = 5.0 V, RL = 390 n, CL = 50 pF |
02 |
6 |
32 |
ns |
Propagation delay time from B to A < B |
tPHL7 |
VCC = 5.0 V, RL = 390 n, CL = 50 pF |
02 |
3 |
26 |
ns |
Propagation delay time from A to A > B |
tPHL8 |
VCC = 5.0 V, RL = 390 n, CL = 50 pF |
02 |
3 |
25 |
ns |
Propagation delay time from B to A > B |
tPHL9 |
VCC = 5.0 V, RL = 390 n, CL = 50 pF |
02 |
6 |
35 |
ns |
11 Not more than one output should be shorted at one time.
21 ICC is measured with outputs open, A = B grounded, and all other inputs at 4.5 V.
31 The longest gate level propagation delay paths are not tested (5 gate levels); however, they can be calculated:
t = tP1 maximum + tP2 maximum - tP4 minimum.
41 Gate level references are made with respect to the logic diagram.
6