TABLE III. Group A inspection for device type 03.
Terminal conditions (pins not designated may be H > 2.0 V, or L < 0.8 V, or open).
Subgroup |
Symbol |
MIL- STD-883 method |
Case J, K, L, Z |
13 |
14 |
15 |
16 |
17 |
18 |
19 |
20 |
21 |
22 |
23 |
24 |
Meas. terminal |
Test limits |
||
Test No. |
2 MR |
2 E 0 |
2 E 1 |
2D0 |
2Q0 |
2D1 |
2Q1 |
2D2 |
2Q2 |
2D3 |
2Q3 |
VCC |
Min |
Max |
Unit |
||||
10 TC = 125°C " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " |
tPHL2 " " " " " " " " " " " " " " " |
3003 Fig 6 " " " " " " " " " " " " " " |
210 211 212 213 214 215 216 217 218 219 220 221 222 223 224 225 |
5.0 V " " " " " " " " " " " " " " " |
IN " " " GND " " " |
GND " " " IN " " " |
IN IN |
OUT OUT |
IN IN |
OUT OUT |
IN IN |
OUT OUT |
IN IN |
OUT OUT |
5.0 V " " " " " " " " " " " " " " " |
1D0-1Q0 1D1-1Q1 1D2-1Q2 1D3-1Q3 1D0-1Q0 1D1-1Q1 1D2-1Q2 1D3-1Q3 2D0-2Q0 2D1-2Q1 2D2-2Q2 2D3-2Q3 2D0-2Q0 2D1-2Q1 2D2-2Q2 2D3-2Q3 |
3 " " " " " " " " " " " " " " " |
37 " " " " " " " " " " " " " " " |
ns " " " " " " " " " " " " " " " |
tPHL3 " " " " " " " " " " " " " " " |
3003 Fig 6-C " " " " " " " " " " " " " " |
226 227 228 229 230 231 232 233 234 235 236 237 238 239 240 241 |
IN " " " " " " " |
IN " " " GND " " " |
GND " " " IN " " " |
5.0 V " " " " " " " |
OUT OUT |
5.0 V " " " " " " " |
OUT OUT |
5.0 V " " " " " " " |
OUT OUT |
5.0 V " " " " " " " |
OUT OUT |
" " " " " " " " " " " " " " " " |
1 MR -1Q0 1 MR -1Q1 1 MR -1Q2 1 MR -1Q3 1 MR -1Q0 1 MR -1Q1 1 MR -1Q2 1 MR -1Q3 2 MR -2Q0 2 MR -2Q1 2 MR -2Q2 2 MR -2Q3 2 MR -2Q0 2 MR -2Q1 2 MR -2Q2 2 MR -2Q3 |
" " " " " " " " " " " " " " " " |
" " " " " " " " " " " " " " " " |
" " " " " " " " " " " " " " " " |
|
11 |
Same tests, terminal conditions and limits as for subgroup 10, except TC = -55°C. |