TABLE III. Group A inspection for all device type 01 - Continued. 11
Subgroup |
Symbol |
Test no. |
Conditions R1 = 10 kν, IK = 10 mA unless otherwise specified |
Measured value |
See figure |
Notes |
Limits |
Unit |
|
Min |
Max |
||||||||
4 TA = +25°C |
NO |
28 |
IK = 10 mA, BW = 0.1 Hz to 10 Hz |
NO |
5 |
41 |
20.00 |
∝Vp-p |
|
5 TA = +125°C |
VREF 1T |
29 |
VKA = VREF |
CALC |
VREF = VR1 - VR6 |
-44.00 |
44.00 |
mV |
|
6 TA = -55°C |
VREF 1T |
30 |
VKA = VREF |
CALC |
VREF = VR1 - VR11 |
-44.00 |
44.00 |
mV |
|
VREF 1T |
31 |
VKA = VREF |
CALC |
VREF = VR11 - VR6 |
-44.00 |
44.00 |
mV |
||
VREF 1T |
32 |
R2 = 8 |
CALC |
3 |
IREF = VR2 - VR3 |
-3.00 |
3.00 |
∝A |
11 For devices marked with the "Q" certification mark, the parameters listed herein may be guaranteed if not tested to the limits specified herein in accordance with the manufacturer's QM plan.
21 VKA = VREF ( 1+ (R1 1 R2 )) + IREF x R2 (see figure 3).
31 ZKA = VKA 1 IK, f < 1 kHz.
41 If not tested, shall be guaranteed to the limits specified in table III herein.