MIL-M-38510/148B
TABLE I. Electrical performance characteristics for device type 02. 1/
Test |
Symbol |
Conditions -55°C = TA = +125°C VREF = 15 V, unless otherwise specified |
Device type |
Limits |
Unit |
|
Min |
Max |
|||||
Minimum operating current |
IMIN |
VZ = 2.48 V, TA = +25°C |
02 |
260 |
∝A |
|
VZ = 2.465 V, TA = +125°C |
340 |
|||||
VZ = 2.465 V, TA = -55°C |
200 |
|||||
Voltage reference |
VZ |
IR = 400 ∝A, TA = +25°C |
02 |
2.495 |
2.505 |
V |
IR = 400 ∝A, TA = -55°C, +125°C |
2.480 |
2.520 |
||||
IR = 1 mA, TA = +25°C |
2.495 |
2.505 |
||||
IR = 1 mA, TA = -55°C, +125°C |
2.480 |
2.520 |
||||
IR = 10 mA, TA = +25°C |
2.490 |
2.510 |
||||
IR = 10 mA, TA = -55°C, +125°C |
2.480 |
2.520 |
||||
Load regulation |
VZload |
IR = 400 ∝A, 10 mA |
02 |
-10.0 |
10.0 |
mV |
Voltage adjust reference |
VADJ |
ADJ = 600 mV |
02 |
2.500 |
V |
|
ADJ = VREF - 600 mV |
2.500 |
|||||
Reference adjustment |
VZADJ |
02 |
100.0 |
mV |
||
Impedance |
VZ / IZ |
400 ∝A < IZ < 10 mA |
02 |
1.0 |
Ohms |
|
Delta voltage / delta temperature |
VZ / dT |
IR = 1 mA, from -55°C to +25°C |
02 |
15 |
mV |
|
IR = 1 mA, from +25°C to +125°C |
15 |
|||||
Noise |
NO |
IR = 1 mA, BW = 0.1 Hz to 10 Hz |
02 |
30 |
∝Vp-p |
1/ For devices marked with the "Q" certification mark, the parameters listed herein may be guaranteed if not tested to the limits specified herein in accordance with the manufacturer's QM plan.