MIL-M-38510/790
TABLE I. Electrical performance characteristics - Continued.
Test |
Symbol |
Conditions -55°C ≤ TC ≤ +125°C Unless otherwise specified |
0evice type |
Limits |
Units |
|
Min |
Max |
|||||
From strobe to W |
tLZ2 |
VCC = 5.0 V CL = 50 pF RL = 280 Ω |
05 |
2.0 |
22.0 |
ns |
From select to Y |
tPLH1 |
06 |
2.0 |
22.0 |
ns |
|
07 |
18.5 |
|||||
From select to Y |
tPHL1 |
06 |
2.0 |
22.0 |
ns |
|
07 |
18.5 |
|||||
From data to Y |
tPLH2 |
06 |
2.0 |
12.0 |
ns |
|
07 |
10.0 |
|||||
From data to Y |
tPHL2 |
06 |
2.0 |
11.0 |
ns |
|
07 |
10.0 |
|||||
From output control to Y |
tZH |
05, 06 |
2.0 |
28.0 |
ns |
|
07 |
28.0 |
|||||
08 |
30.0 |
|||||
From output control to Y |
tZL |
05, 06 |
2.0 |
30.0 |
ns |
|
07 |
30.0 |
|||||
08 |
31.0 |
|||||
From output control to Y |
tHZ |
05, 06 |
2.0 |
24.0 |
ns |
|
07 |
24.0 |
|||||
08 |
18.0 |
|||||
From output control to Y |
tLZ |
05, 06 |
2.0 |
22.0 |
ns |
|
07 |
22.0 |
|||||
08 |
20.0 |
1/ Not more than one output should be shorted at one time.
2/ For device type 06, IIL minimum limit shall be -0.005 mA for circuit B.