MIL-M-38510/755B
Device types 03 Device type 05
Input |
Operation |
|
OE |
T/R |
|
L L H |
L H x |
Bus B data to bus A Bus A data to bus B High impedance state |
Device type 06 Device type 07
Input |
Valid direction I/P - O/P |
Output |
||
OE |
T/R |
Applied inputs |
||
H L L L L |
x H H L L |
x H L H L |
x A to B A to B B to A B to A |
x L H L H |
Device types 08 and 09
Inputs |
Data I/O 1/ |
Operation |
||||||
G |
DIR |
CAB |
CBA |
SAB |
SBA |
A0-A7 |
B0-B7 |
|
H H H |
x x x |
H or L τ x |
H or L x τ |
x x x |
x x x |
Input |
Input |
Isolation Clock A data into A register Clock B data into B register |
L L L L |
H H H H |
x τ H or L τ |
x x x x |
L L H H |
x x x x |
Input |
Output |
Real time A data input to B bus 2/ Clock A data into A register 2/ A register data to B bus 2/ Clock A data into A register and output to B bus 2/ |
L L L L |
L L L L |
x x x x |
x τ H or L τ |
x x x x |
L L H H |
Output |
Input |
Real time B data to A bus 2/ Clock B data into B register 2/ B register data into B bus 2/ Clock B data into B register and output to A bus 2/ |
1/ The data output functions may enabled or disabled by various signals at the G and DIR inputs. Data input functions are always enabled; i.e., data at the bus pins will be stored on every low-to-high transition of the clock inputs.
2/ For device type 09, these data inputs are inverted.
H = High level
L = Low level
Z = High-impedance x = Don't care
τ = Low-to-high transition of the clock.
FIGURE 2. Truth tables.