MIL-M-38510/755B
TABLE I. Electrical performance characteristics - Continued.
Test and MIL-STD-883 test method |
Symbol |
Test Conditions 1/ -55°C = TC = +125°C +3.0 V = VCC = +5.5 V unless otherwise specified |
Device type 2/ |
VCC |
Group A subgroups |
Limits 1/ |
Unit |
||
Min |
Max |
||||||||
Propagation delay time, output disable, 0E, G, 0EBA or 0EAB to output 3003 |
tPHZ1, tPLZ1 4/ 5/ 14/ 15/ |
CL = 50 pF minimum RL = 500ν see figure 4 |
03 |
3.0 V |
9, 11 |
1.0 |
12.0 |
ns |
|
10 |
1.0 |
14.0 |
|||||||
05 |
9, 11 |
1.0 |
15.0 |
||||||
10 |
1.0 |
16.5 |
|||||||
06 |
9, 11 |
1.0 |
7.5 |
||||||
10 |
1.0 |
8.0 |
|||||||
07 |
9, 11 |
1.0 |
7.5 |
||||||
10 |
1.0 |
8.0 |
|||||||
08, 09 |
9, 11 |
1.0 |
12.0 |
||||||
10 |
1.0 |
14.0 |
|||||||
M |
03 |
9 |
1.0 |
12.0 |
|||||
D |
1.0 |
12.0 |
|||||||
P, L, R, F |
1.0 |
12.0 |
|||||||
CL = 50 pF minimum RL = 500ν see figure 4 |
03 |
4.5 V |
9, 11 |
1.0 |
9.0 |
ns |
|||
10 |
1.0 |
10.5 |
|||||||
05 |
9, 11 |
1.0 |
12.0 |
||||||
10 |
1.0 |
13.0 |
|||||||
06 |
9, 11 |
1.0 |
6.0 |
||||||
10 |
1.0 |
6.5 |
|||||||
07 |
9, 11 |
1.0 |
6.0 |
||||||
10 |
1.0 |
6.5 |
|||||||
08, 09 |
9, 11 |
1.0 |
10.0 |
||||||
10 |
1.0 |
11.5 |
|||||||
M |
03 |
9 |
1.0 |
9.0 |
|||||
D |
1.0 |
9.0 |
|||||||
P, L, R, F |
1.0 |
9.0 |
|||||||
Propagation delay time, output disable, DIR to bus 3003 |
tPHZ2, tPLZ2 14/ 15/ |
CL = 50 pF minimum RL = 500ν see figure 4 |
08, 09 |
3.0 V |
9, 11 |
1.0 |
14.0 |
ns |
|
10 |
1.0 |
16.5 |
|||||||
08, 09 |
4.5 V |
9, 11 |
1.0 |
10.0 |
|||||
10 |
1.0 |
12.0 |
1/ Each input/output, as applicable, shall be tested at the specified temperature for the specified limits. 0utput terminals not designated shall be high level logic, low level logic, or open, except as follows:
a. VIC (pos) tests, the GND terminal can be open. TC = +25°C. b. VIC (neg) tests, the VCC terminal shall be open. TC = +25°C.
c. All ICC tests, the output terminal shall be open. When performing these tests, the current meter shall be placed in the circuit such that all current flows through the meter.
For negative and positive voltage and current values, the sign designates the potential difference in reference to GND and the direction of current flow, respectively, and the absolute value of the magnitude, not the sign, is relative to the minimum and maximum limits, as applicable, listed herein.
2/ The word "All" in the device type column means non-RHA and preirradiation limits for all devices. Where. M, D, P, L, R, and