TA8LE III. Group A inspection for device type 01 - Continued.
Terminal conditions (pins not designated may be high � 2.0 V or low s 0.8 V, or open).
Subgroup |
Symbol |
MIL- STD- 883 method |
Cases |
Measured terminal |
Limits |
Unit |
|||||||||||||||
A,8,C,D |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
|||||||
2, X, 21 |
2 |
3 |
4 |
6 |
8 |
9 |
10 |
12 |
13 |
14 |
16 |
18 |
19 |
20 |
|||||||
Test no. |
1A |
18 |
1Y |
2A |
28 |
2Y |
GND |
3Y |
3A |
38 |
4Y |
4A |
48 |
VCC |
Min |
Max |
|||||
10 TC=+125°C |
tPHL1 |
3003 (Fig. 3) " " |
82 83 84 85 |
IN |
GND |
OUT |
IN |
GND |
OUT |
" " " " |
OUT |
IN |
GND |
OUT |
IN |
GND |
5.0 V " " " |
1Y 2Y 3Y 4Y |
2 " " " |
15.5 " " " |
ns " " " |
tPHL2 |
" " " " |
86 87 88 89 |
IN |
2.7 V |
OUT |
IN |
2.7 V |
OUT |
" " " " |
OUT |
IN |
2.7 V |
OUT |
IN |
2.7 V |
" " " " |
1Y 2Y 3Y 4Y |
" " " " |
" " " " |
" " " " |
|
11 |
Same tests, terminal conditions and limits as for subgroup 10, except TC = -55°C. |
11 IIL limits for device type 01, circuit 8, are -50 µA minimum and -750 µA maximum.
21 Cases 2 and X pins not designated are NC.