MIL-M-38510/75C
TABLE I. Electrical performance characteristics - Continued.
Test |
Symbol |
Conditions -55°C ≤ TC ≤ +125°C |
Device type |
Limits |
Units |
|
Min |
Max |
|||||
Propagation delay low to high level |
tPLH1 |
VCC = 5.0 V From A or B, CL = 50 pF B or A = L, RL = 280 0 C = L |
02 |
2.0 |
19.5 |
ns |
Propagation delay high to low level |
tPHL1 |
VCC = 5.0 V From A or B, CL = 50 pF B or A = L, RL = 280 0 C = L |
02 |
2.0 |
22.0 |
ns |
Propagation delay low to high level |
tPLH2 |
VCC = 5.0 V From A or B, CL = 50 pF B or A = H, RL = 280 0 C = L |
02 |
2.0 |
18.5 |
ns |
Propagation delay high to low level |
tPHL2 |
VCC = 5.0 V From A or B, CL = 50 pF B or A = H, RL = 280 0 C = L |
02 |
2.0 |
20.0 |
ns |
Propagation delay low to high level |
tPLH3 |
VCC = 5.0 V From A or B, CL = 50 pF B or A = L, RL = 280 0 C = H |
02 |
2.0 |
22.0 |
ns |
Propagation delay high to low level |
tPHL3 |
VCC = 5.0 V From A or B, CL = 50 pF B or A = L, RL = 280 0 C = H |
02 |
2.0 |
15.5 |
ns |
Propagation delay low to high level |
tPLH4 |
VCC = 5.0 V From A or B, CL = 50 pF B or A = H, RL = 280 0 C = H |
02 |
2.0 |
18.5 |
ns |
Propagation delay high to low level |
tPHL4 |
VCC = 5.0 V From A or B, CL = 50 pF B or A = H, RL = 280 0 C = H |
02 |
2.0 |
17.0 |
ns |
Propagation delay low to high level |
tPLH5 |
VCC = 5.0 V From C CL = 50 pF to A = B RL = 280 0 |
02 |
2.0 |
18.0 |
ns |
Propagation delay high to low level |
tPHL5 |
VCC = 5.0 V From C CL = 50 pF to A = B RL = 280 0 |
02 |
2.0 |
21.5 |
ns |
Propagation delay low to high level |
tPLH6 |
VCC = 5.0 V From C CL = 50 pF to A ≠ B RL = 280 0 |
02 |
2.0 |
17.5 |
ns |
Propagation delay high to low level |
tPHL6 |
VCC = 5.0 V From C CL = 50 pF to A ≠ B RL = 280 0 |
02 |
2.0 |
18.0 |
ns |
1/ Not more than one output should be shorted at one time.
5
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business