TA8LE III. Group A inspection for device type 04 - Continued.
Terminal conditions (pins not designated are open)
Subgroup |
Symbol |
MIL- STD-883 method |
Cases A, 8, D |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
Measured terminal |
Test limits |
Unit |
|
Case C |
11 |
12 |
1 |
14 |
13 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
|||||||
Test no. |
NC |
NC |
A |
vCC |
8 |
C |
D |
E |
F |
G |
GND |
Y |
H |
I |
Min |
Max |
|||||
1 TC = +25°C |
IOS |
3011 |
35 |
GND |
5.5 v |
GND |
GND |
GND |
GND |
GND |
GND |
GND |
GND |
GND |
GND |
Y |
-40 |
-100 |
mA |
||
ICCL |
3005 |
36 |
5.5 v |
" |
5.5 v |
5.5 v |
5.5 v |
5.5 v |
5.5 v |
5.5 v |
" |
5.5 v |
5.5 v |
vCC |
14 |
" |
|||||
ICCH |
3005 |
37 |
GND |
" |
GND |
GND |
GND |
GND |
GND |
GND |
" |
GND |
GND |
vCC |
11 |
" |
|||||
vIC |
38 39 40 41 42 43 44 45 46 |
-12 mA |
4.5 v " " " " " " " " |
-12 mA |
-12 mA |
-12 mA |
-12 mA |
-12 mA |
-12 mA |
" " " " " " " " " |
-12 mA |
-12 mA |
A 8 C D E F G H I |
-1.5 " " " " " " " " |
v " " " " " " " " |
||||||
2 |
Same tests, terminal conditions, and limits as for subgroup 1, except TC = +125°C and vIC tests are omitted. |
||||||||||||||||||||
3 |
Same tests, terminal conditions, and limits as for subgroup 1, except TC = -55°C and vIC tests are omitted. |
||||||||||||||||||||
9 TC = +25°C |
tPHL1 |
3003 |
47 |
IN |
5.0 v |
2.4 v |
GND |
GND |
GND |
GND |
GND |
GND |
OUT |
GND |
GND |
A to Y |
2 |
13 |
ns |
||
tPLH1 |
Fig. 4 |
48 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
A to Y |
" |
14 |
" |
|||
10 TC = +125°C |
tPHL1 |
" |
49 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
A to Y |
" |
18 |
" |
||
tPLH1 |
" |
50 |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
" |
A to Y |
" |
18 |
" |
|||
11 |
Same tests, terminal conditions, and limits as for subgroup 10, except TC = -55°C. |
For Parts Inquires call Parts Hangar, Inc (727) 493-0744