MIL-M-38510/346C
TABLE I. Electrical performance characteristics - Continued.
Test |
Symbol |
Conditions -55°C ≤ TC ≤ +125°C |
Device type |
Limits |
Unit |
|
Min |
Max |
|||||
Propagation delay time off-state to low level |
VCC = 5.0 V, CL = 50 pF ± 10%, See figure 4 |
|||||
OE to Q |
tPZL1 |
01 |
2.0 |
10.0 |
ns |
|
04 |
2.0 |
10.0 |
||||
OE to Q |
tPZL1 |
02 |
2.0 |
9.0 |
ns |
|
03 |
2.5 |
10.0 |
||||
Propagation delay time off-state to high level |
||||||
OE to Q |
tPZH1 |
01 |
2.0 |
15.0 |
ns |
|
04 |
2.0 |
10.0 |
||||
OE to Q |
tPZH1 |
02 |
2.0 |
12.5 |
ns |
|
03 |
2.0 |
9.5 |
1/ Not more than one output should be shorted at a time.
TABLE II. Electrical test requirements.
MIL-PRF-38535 test requirements |
Subgroups (see table III) |
|
Class S devices |
Class B devices |
|
Interim electrical parameters |
1 |
1 |
Final electrical test parameters |
1*, 2, 3, 7, 9, 10, 11 |
1*, 2, 3, 7, 9 |
Group A test requirements |
1, 2, 3, 7, 8, 9, 10, 11 |
1, 2, 3, 7, 8, 9, 10, 11 |
Group B electrical test parameters when using the method 5005 QCI option |
1, 2, 3, 7, 8, 9, 10, 11 |
N/A |
Group C end-point electrical parameters |
1, 2, 3, 7, 8, 9, 10, 11 |
1, 2, 3 |
Group D end-point electrical parameters |
1, 2, 3 |
1, 2, 3 |
*PDA applies to subgroup 1.
7
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business