MIL-M-38510/311C
NOTES:
1. The pulse generator has the following characteristics: Vgen = 3.0 V, t1 ≤ 15 ns, t0 ≤ 6 ns, tP = 500 ns, PRR ≤ 1.0 MHz, and ZOUT 50ν.
2. CL = 50 pF ±10% and includes probe and jig capacitance.
3. All diodes are 1N3064, or equivalent.
FIGURE 4. Switching time test circuit.