TA8LE III. Group A inspection for device type 02 - Continued.
Symbol |
MIL- STD-833 method |
Cases C,D, T, and Y |
Terminal conditions 1/ |
Measured terminal |
Test limits |
Unit |
||||||||||||||||||
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
Subgroup 9 TA = 25°C |
Subgroup 10 TA = 125°C |
Subgroup 11 TA = -55°C |
||||||||
Symbol |
1Y |
1A |
18 |
1C |
1D |
NC |
VSS |
NC |
2A |
28 |
2C |
2D |
2Y |
VDD |
||||||||||
Test No. |
Min |
Max |
Min |
Max |
Min |
Max |
||||||||||||||||||
tTHL " " " " " " " |
3004 Fig. 3 " " " " " " |
124 125 126 127 128 129 130 131 |
OUT " " " |
IN 5.0V " " " " " " |
5.0V IN 5.0V " " " " " |
5.0V " IN 5.0V " " " " |
5.0V " " IN 5.0V " " " |
GND " " " " " " " |
5.0V " " " IN 5.0V " " |
5.0V " " " " IN 5.0V " |
5.0V " " " " " IN 5.0V |
5.0V " " " " " " IN |
OUT " " " |
5.0V " " " " " " " |
1Y 1Y 1Y 1Y 2Y 2Y 2Y 2Y |
10 " " " " " " " |
200 " " " " " " " |
14 " " " " " " " |
280 " " " " " " " |
10 " " " " " " " |
200 " " " " " " " |
ns " " " " " " " |
||
tTLH " " " " " " " |
3004 Fig. 3 " " " " " " |
132 133 134 135 136 137 138 139 |
OUT " " " |
IN 5.0V " " " " " " |
" IN 5.0V " " " " " |
" " IN 5.0V " " " " |
" " " IN 5.0V " " " |
" " " " " " " " |
" " " " IN 5.0V " " |
" " " " " IN 5.0V 5.0V |
" " " " " " IN 5.0V |
5.0V " " " " " " IN |
OUT " " " |
" " " " " " " " |
1Y 1Y 1Y 1Y 2Y 2Y 2Y 2Y |
" " " " " " " " |
" " " " " " " " |
" " " " " " " " |
" " " " " " " " |
" " " " " " " " |
" " " " " " " " |
" " " " " " " " |
||
Measured terminal |
Test limits |
Unit |
||||||||||||||||||||||
Subgroup 12 TA = 25°C |
||||||||||||||||||||||||
Min |
Max |
|||||||||||||||||||||||
tPHL " " " " " " " |
3003 Fig. 3 " " " " " " |
140 141 142 143 144 145 146 147 |
OUT " " " |
IN 10.0V " " " " " " |
10.0V IN 10.0V " " " " " |
10.0V 10.0V IN 10.0V " " " " |
10.0V 10.0V 10.0V IN 10.0V " " " |
GND " " " " " " " |
10.0V " " " IN 10.0V " " |
10.0V " " " " IN 10.0V " |
10.0V " " " " " IN 10.0V |
10.0V " " " " " " IN |
OUT " " " |
10.0V " " " " " " " |
1A to 1Y 18 to 1Y 1C to 1Y 1D to 1Y 2A to 2Y 28 to 2Y 2C to 2Y 2D to 2Y |
6 " " " " " " " |
120 " " " " " " " |
ns " " " " " " " |
||||||
tPLH " " " " " " " |
" " " " " " " " |
148 149 150 151 152 153 154 155 |
OUT " " " |
IN 10.0V " " " " " " |
" IN 10.0V " " " " " |
" " IN 10.0V " " " " |
" " " IN 10.0V " " " |
" " " " " " " " |
" " " " IN 10.0V " " |
" " " " " IN 10.0V " |
" " " " " " IN 10.0V |
10.0V " " " " " " IN |
OUT " " " |
" " " " " " " " |
1A to 1Y 18 to 1Y 1C to 1Y 1D to 1Y 2A to 2Y 28 to 2Y 2C to 2Y 2D to 2Y |
" " " " " " " " |
" " " " " " " " |
" " " " " " " " |
||||||
tTHL " " " " " " " |
3004 Fig. 3 " " " " " " |
156 157 158 159 160 161 162 163 |
OUT " " " |
IN 10.0V " " " " " " |
" IN 10.0V " " " " " |
" " IN 10.0V " " " " |
" " " IN 10.0V " " " |
" " " " " " " " |
" " " " IN 10.0V " " |
" " " " " IN 10.0V " |
" " " " " " IN 10.0V |
10.0V " " " " " " IN |
OUT " " " |
" " " " " " " " |
1Y 1Y 1Y 1Y 2Y 2Y 2Y 2Y |
5 " " " " " " " |
100 " " " " " " " |
" " " " " " " " |
||||||
tTLH " " " " " " " |
" " " " " " " " |
164 165 166 167 168 169 170 171 |
OUT " " " |
IN 10.0V " " " " " " |
" IN 10.0V " " " " " |
" " IN 10.0V " " " " |
" " " IN 10.0V " " " |
" " " " " " " " |
" " " " IN 10.0V 10.0V 10.0V |
" " " " " IN 10.0V 10.0V |
" " " " " " IN 10.0V |
10.0V " " " " " " IN |
OUT " " " |
" " " " " " " " |
1Y 1Y 1Y 1Y 2Y 2Y 2Y 2Y |
" " " " " " " " |
" " " " " " " " |
" " " " " " " " |
See footnotes at end of table.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business