TABLE III. Group A inspection for device type 02 - Continued. Terminal conditions (pins not designated are open, high level or low level)
Subgroup |
Symbol |
MIL- STD-883 method |
Cases A,B,C,D |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
Measured terminal |
Limits |
Unit |
|
Test no. |
1A |
1Y |
2A |
2Y |
3A |
3Y |
GND |
4Y |
4A |
5Y |
5A |
6Y |
6A |
VCC |
Min |
Max |
|||||
1 TC=25°C |
IOS |
3011 " " " " " |
49 50 51 52 53 54 |
GND |
GND |
GND |
GND |
GND |
GND |
GND " " " " " |
GND |
GND |
GND |
GND |
GND |
GND |
5.5V " " " " " |
1Y 2Y 3Y 4Y 5Y 6Y |
-18 " " " " " |
-55 " " " " " |
mA " " " " " |
ICCH |
3005 |
55 |
GND |
GND |
GND |
" |
GND |
GND |
GND |
" |
VCC |
36 |
" |
||||||||
ICCL |
3005 |
56 |
5.5V |
5.5V |
5.5V |
" |
5.5V |
5.5V |
5.5V |
" |
VCC |
60 |
" |
||||||||
2 |
Same tests, terminal conditions and limits as for subgroup 1, except TC = 125°C VIC tests are omitted, and VIN = 0.5 V for VOH1 testing. |
||||||||||||||||||||
3 |
Same tests, terminal conditions and limits as for subgroup 1, except TC = -55°C and VIC tests are omitted. |
||||||||||||||||||||
9 TC=25°C |
tPHL |
3003 (Fig. 3) " " " " |
57 58 59 60 61 62 |
IN |
OUT |
IN |
OUT |
IN |
OUT |
GND " " " " " |
OUT |
IN |
OUT |
IN |
OUT |
IN |
5.0V " " " " " |
1A to 1Y 2A to 2Y 3A to 3Y 4A to 4Y 5A to 5Y 6A to 6Y |
5 " " " " " |
26 " " " " " |
ns " " " " " |
tPLH |
" " " " " " |
63 64 65 66 67 68 |
IN |
OUT |
IN |
OUT |
IN |
OUT |
" " " " " " |
OUT |
IN |
OUT |
IN |
OUT |
IN |
" " " " " " |
1A to 1Y 2A to 2Y 3A to 3Y 4A to 4Y 5A to 5Y 6A to 6Y |
" " " " " " |
28 " " " " " |
" " " " " " |
|
10 TC=125°C |
tPHL |
" " " " " " |
69 70 71 72 73 74 |
IN |
OUT |
IN |
OUT |
IN |
OUT |
" " " " " " |
OUT |
IN |
OUT |
IN |
OUT |
IN |
" " " " " " |
1A to 1Y 2A to 2Y 3A to 3Y 4A to 4Y 5A to 5Y 6A to 6Y |
" " " " " " |
35 " " " " " |
" " " " " " |
tPLH |
" " " " " " |
75 76 77 78 79 80 |
IN |
OUT |
IN |
OUT |
IN |
OUT |
" " " " " " |
OUT |
IN |
OUT |
IN |
OUT |
IN |
" " " " " " |
1A to 1Y 2A to 2Y 3A to 3Y 4A to 4Y 5A to 5Y 6A to 6Y |
" " " " " " |
40 " " " " " |
" " " " " " |
|
11 |
Same tests, terminal conditions and limits as for subgroup 10, except TC= -55°C. |
1/ 2.0 V, then 1.1 V.
2/ 0.6 V, then 1.5 V.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744