TABLE III. Group A inspection for device type 04 - Continued.
Terminal conditions (pins not designated may be H � 2.0 V, or L ≤ 0.8 V, or open).
Subgroup |
Symbol |
MIL- STD-883 method |
Cases E, F |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
Meas. terminal |
Test limits |
||
Test No. |
2Y |
2W |
B |
2C0 |
2C1 |
2C2 |
2C3 |
GND |
1C3 |
1C2 |
1C1 |
1C0 |
A |
1W |
1Y |
VCC |
Min |
Max |
Unit |
||||
9 TC = 25°C " " |
tPLH4 " " " |
3003 (Fig 5) " " |
106 107 108 109 |
OUT OUT |
GND GND IN IN |
GND GND |
5.0 V |
5.0 V |
GND " " " |
5.0 V |
5.0 V |
GND GND |
IN IN GND GND |
OUT OUT |
5.0 V " " " |
A to 1W A to 2W B to 1W B to 2W |
6 " " " |
26 " " " |
ns " " " |
||||
10 TC = 125°C " " " " " " " " " " " " " " " " " " " " " " " " " " " " " " |
tPHL1 " " " " " " " |
" " " " " " " " |
110 111 112 113 114 115 116 117 |
OUT " " " |
GND GND 5.0 V 5.0 V GND GND 5.0 V 5.0 V |
IN |
IN |
IN |
IN |
" " " " " " " " |
IN |
IN |
IN |
IN |
GND 5.0 V GND 5.0 V GND 5.0 V GND 5.0 V |
OUT " " " |
" " " " " " " " |
1C0 to 1Y 1C1 to 1Y 1C2 to 1Y 1C3 to 1Y 2C0 to 2Y 2C1 to 2Y 2C2 to 2Y 2C3 to 2Y |
3 " " " " " " " |
41 " " " " " " " |
" " " " " " " " |
||
tPLH1 " " " " " " " |
" " " " " " " " |
118 119 120 121 122 123 124 125 |
OUT " " " |
GND GND 5.0 V 5.0 V GND GND 5.0 V 5.0 V |
IN |
IN |
IN |
IN |
" " " " " " " " |
IN |
IN |
IN |
IN |
GND 5.0 V GND 5.0 V GND 5.0 V GND 5.0 V |
OUT " " " |
" " " " " " " " |
1C0 to 1Y 1C1 to 1Y 1C2 to 1Y 1C3 to 1Y 2C0 to 2Y 2C1 to 2Y 2C2 to 2Y 2C3 to 2Y |
" " " " " " " " |
39 " " " " " " " |
" " " " " " " " |
|||
tPHL2 " " " " " " " |
" " " " " " " " |
126 127 128 129 130 131 132 133 |
OUT " " " |
GND GND 5.0 V 5.0 V GND GND 5.0 V 5.0 V |
IN |
IN |
IN |
IN |
" " " " " " " " |
IN |
IN |
IN |
IN |
GND 5.0 V GND 5.0 V GND 5.0 V GND 5.0 V |
OUT " " " |
" " " " " " " " |
1C0 to 1W 1C1 to 1W 1C2 to 1W 1C3 to 1W 2C0 to 2W 2C1 to 2W 2C2 to 2W 2C3 to 2W |
" " " " " " " " |
25 " " " " " " " |
" " " " " " " " |
|||
tPLH2 " " " " " " " |
" " " " " " " " |
134 135 136 137 138 139 140 141 |
OUT " " " |
GND GND 5.0 V 5.0 V GND GND 5.0 V 5.0 V |
IN |
IN |
IN |
IN |
" " " " " " " " |
IN |
IN |
IN |
IN |
GND 5.0 V GND 5.0 V GND 5.0 V GND 5.0 V |
OUT " " " |
" " " " " " " " |
1C0 to 1W 1C1 to 1W 1C2 to 1W 1C3 to 1W 2C0 to 2W 2C1 to 2W 2C2 to 2W 2C3 to 2W |
" " " " " " " " |
24 " " " " " " " |
" " " " " " " " |
See note at end of device type 04.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business