TABLE III. Group A inspection for device type 03 - Continued.
Terminal conditions (pins not designated may be H � 2.0 V, or L ≤ 0.8 V, or open).
Subgroup |
Symbol |
MIL- STD-883 method |
Cases E, F |
1 |
2 |
3 |
4 |
5 |
6 |
7 |
8 |
9 |
10 |
11 |
12 |
13 |
14 |
15 |
16 |
Meas. terminal |
Test limits |
||
Test No. |
1G |
B |
1C3 |
1C2 |
1C1 |
1C0 |
1Y |
GND |
2Y |
2C0 |
2C1 |
2C2 |
2C3 |
A |
2G |
VCC |
Min |
Max |
Unit |
||||
10 TC = 125°C " " " " " " " " " " |
tPHL2 " " " |
3003 (Fig 5) " " |
109 110 111 112 |
GND GND |
GND IN GND IN |
5.0 V |
5.0 V |
GND GND |
OUT OUT |
GND " " " |
OUT OUT |
GND GND |
5.0 V |
5.0 V |
IN GND IN GND |
GND GND |
5.0 V " " " |
A to 1Y B to 1Y A to 2Y B to 2Y |
6 " " " |
44 " " " |
ns " " " |
||
tPLH2 " " " |
" " " " |
113 114 115 116 |
GND GND |
GND IN GND IN |
5.0 V |
5.0 V |
GND GND |
OUT OUT |
" " " " |
OUT OUT |
GND GND |
5.0 V |
5.0 V |
IN GND IN GND |
GND GND |
" " " " |
A to 1Y B to 1Y A to 2Y B to 2Y |
" " " " |
42 " " " |
" " " " |
|||
tPHL3 tPHL3 |
" " |
117 118 |
IN |
GND GND |
5.0 V |
OUT |
" " |
OUT |
5.0 V |
GND GND |
IN |
" " |
1G to 1Y 2G to 2Y |
" " |
32 32 |
" " |
|||||||
tPLH3 tPLH3 |
" " |
119 120 |
IN |
GND GND |
5.0 V |
OUT |
" " |
OUT |
5.0 V |
GND GND |
IN |
" " |
1G to 1Y 2G to 2Y |
" " |
42 42 |
" " |
|||||||
11 |
Same tests, terminal conditions and limits as subgroup 10, except TC = -55°C. |
1/ A = 3.0 V minimum, B = 0.0 V or GND.
2/ H > 1.5 V; L < 1.5 V.
Only attributes data is required for subgroups 7 and 8.
For Parts Inquires call Parts Hangar, Inc (727) 493-0744
© Copyright 2015 Integrated Publishing, Inc.
A Service Disabled Veteran Owned Small Business